The Euganean Geothermal Field (EuGF), covering approximately 36 km² in central Veneto, represents a complex hydrothermal system whose recharge area is located about 80 km to the north, in the pre-Alpine region, at altitudes ranging between 1,000 and 2,239 m a.s.l. Fluid ascent, with temperatures reaching between 65 °C and 86 °C, is facilitated by the local fault system (Schio-Vicenza fault), which allows for rapid vertical migration from a depth of 3–4 km, thereby preserving the thermochemical characteristics of the deep reservoir. Monitoring conducted on 24 sampling points (22 wells and 2 springs) integrated field analysis, ion chromatography (IC), and thermodynamic modeling (PHREEQC) using programming languages (Jupyter/Python) and GIS tools. The results demonstrate that the system is not homogeneous but exhibits a continuous hydrogeochemical gradient controlled by the mixing of two distinct end-members: a deep geothermal fluid (Na–Cl facies) in the heart of the Abano and Montegrotto Terme area, and cold infiltration water (Ca–HCO₃ facies). Moving from north (Abano-Montegrotto) to south (Monselice), progressive dilution and fluid cooling lead to an inversion of the classical Chebotarev evolutionary sequence. Finally, the analysis of silica geothermometers and saturation indices confirms a rapid, sub-vertical ascent of fluids, followed by sub-horizontal expansion toward the southern areas of the geothermal basin.

Il Campo Geotermico Euganeo (EuGF), esteso su 36 km² nel Veneto centrale, rappresenta un sistema idrotermale complesso la cui ricarica avviene a circa 80 km a nord, nell'area prealpina, a quote comprese tra i 1000 e i 2239 m s.l.m. La risalita dei fluidi, che raggiungono temperature tra i 65 °C e gli 86 °C, è facilitata dal sistema di faglie locale (faglia Schio-Vicenza) che permette la risalita rapida da profondità di 3-4 km, preservando le caratteristiche termochimiche del serbatoio profondo. Il monitoraggio effettuato su 24 punti (22 pozzi e 2 sorgenti) ha integrato analisi di campo, cromatografia ionica (IC) e modellazione termodinamica (PHREEQC) con l'ausilio di linguaggi di programmazione (Jupyter/Python) e strumenti GIS. I risultati dimostrano che il sistema non è omogeneo, ma presenta un gradiente idrogeochimico continuo controllato dalla miscelazione tra un fluido geotermico profondo (facies Na-Cl) e acque fredde di infiltrazione locale (facies Ca-HCO₃). Procedendo da nord (Abano-Montegrotto) verso sud (Monselice), la progressiva diluizione e il raffreddamento determinano un'inversione della sequenza evolutiva di Chebotarev. Infine, l'analisi dei geotermometri a silice e degli indici di saturazione conferma una risalita rapida e sub-verticale dei fluidi, seguita da una diffusione sub-orizzontale verso le aree meridionali del bacino.

Caratterizzazione idrogeochimica del Bacino Termale Euganeo: implicazioni sull'idrodinamica del sistema acquifero

MARCASSA, ALBERTO
2025/2026

Abstract

The Euganean Geothermal Field (EuGF), covering approximately 36 km² in central Veneto, represents a complex hydrothermal system whose recharge area is located about 80 km to the north, in the pre-Alpine region, at altitudes ranging between 1,000 and 2,239 m a.s.l. Fluid ascent, with temperatures reaching between 65 °C and 86 °C, is facilitated by the local fault system (Schio-Vicenza fault), which allows for rapid vertical migration from a depth of 3–4 km, thereby preserving the thermochemical characteristics of the deep reservoir. Monitoring conducted on 24 sampling points (22 wells and 2 springs) integrated field analysis, ion chromatography (IC), and thermodynamic modeling (PHREEQC) using programming languages (Jupyter/Python) and GIS tools. The results demonstrate that the system is not homogeneous but exhibits a continuous hydrogeochemical gradient controlled by the mixing of two distinct end-members: a deep geothermal fluid (Na–Cl facies) in the heart of the Abano and Montegrotto Terme area, and cold infiltration water (Ca–HCO₃ facies). Moving from north (Abano-Montegrotto) to south (Monselice), progressive dilution and fluid cooling lead to an inversion of the classical Chebotarev evolutionary sequence. Finally, the analysis of silica geothermometers and saturation indices confirms a rapid, sub-vertical ascent of fluids, followed by sub-horizontal expansion toward the southern areas of the geothermal basin.
2025
Hydrogeochemical characterization of the Euganean Thermal Basin: implications for the hydrodynamics of the aquifer system.
Il Campo Geotermico Euganeo (EuGF), esteso su 36 km² nel Veneto centrale, rappresenta un sistema idrotermale complesso la cui ricarica avviene a circa 80 km a nord, nell'area prealpina, a quote comprese tra i 1000 e i 2239 m s.l.m. La risalita dei fluidi, che raggiungono temperature tra i 65 °C e gli 86 °C, è facilitata dal sistema di faglie locale (faglia Schio-Vicenza) che permette la risalita rapida da profondità di 3-4 km, preservando le caratteristiche termochimiche del serbatoio profondo. Il monitoraggio effettuato su 24 punti (22 pozzi e 2 sorgenti) ha integrato analisi di campo, cromatografia ionica (IC) e modellazione termodinamica (PHREEQC) con l'ausilio di linguaggi di programmazione (Jupyter/Python) e strumenti GIS. I risultati dimostrano che il sistema non è omogeneo, ma presenta un gradiente idrogeochimico continuo controllato dalla miscelazione tra un fluido geotermico profondo (facies Na-Cl) e acque fredde di infiltrazione locale (facies Ca-HCO₃). Procedendo da nord (Abano-Montegrotto) verso sud (Monselice), la progressiva diluizione e il raffreddamento determinano un'inversione della sequenza evolutiva di Chebotarev. Infine, l'analisi dei geotermometri a silice e degli indici di saturazione conferma una risalita rapida e sub-verticale dei fluidi, seguita da una diffusione sub-orizzontale verso le aree meridionali del bacino.
Caratterizzazione
Idrogeochimica
Bacino Euganeo
Idrodinamica
File in questo prodotto:
File Dimensione Formato  
MARCASSA_ALBERTO.pdf

Accesso riservato

Dimensione 9.2 MB
Formato Adobe PDF
9.2 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License