DC-DC converters are essential elements in modern power electronics, widely employed to regulate voltage levels across various applications. A critical component in these topologies is the output inductor. To ensure robustness and meet customer requirements, designers typically specify a wide acceptable inductance range, ensuring correct system operation regardless of the specific inductor value chosen by the customer. However, this generally results in non-optimal performance in many cases. The compensation network must guarantee stability across the entire inductance range, often limiting maximum bandwidth and dynamic response because it is optimized for the worst-case scenario rather than actual component values. Consequently, the compromise required to ensure stability and compliance with specifications under critical conditions makes it impossible to optimize performance for all accepted component value combinations. Therefore, converters may suffer from reduced efficiency, as control parameters cannot be optimized for the specific inductance present in the final assembly. Another example of a non optimized parameter is the minimum on-time, which is typically limited conservatively by the worst-case inductance to control output voltage ripple. This imposes unnecessary efficiency losses when higher-value inductors are installed. To overcome these limitations, this thesis proposes an on-board output inductance estimation technique. The primary objective is to enable a more flexible and robust converter design by measuring the actual output inductance during the startup phase. The proposed architecture integrates an Inductor Current Emulator, which estimates inductor current dynamics, along with a High-Side current comparator. By comparing the actual current slope with the emulated reference, the system identifies the inductance threshold in real time. Measuring the output inductance enables several advantages. First, it allows for adaptive compensation of the control loop, maximizing performance and stability across different component selections. Second, it enables adaptive adjustment of the minimum on-time, improving efficiency at light loads when higher-value inductors are used. Third, it enhances system safety by verifying that the output inductance is within acceptable operational ranges during startup, inhibiting switching if components are out of specification. Finally, this approach can expand the functional range of the BOM (Bill of Materials), giving customers greater freedom in component selection while maintaining optimal performance. The analysis and simulations were performed using the Cadence Virtuoso design environment. The results validate the accuracy and robustness of the estimation.
Built-In Self Test for DC-DC Converters: Analysis and Implementation of an Output Inductance Measurement Circuit
BRANDALESE, FABIO
2025/2026
Abstract
DC-DC converters are essential elements in modern power electronics, widely employed to regulate voltage levels across various applications. A critical component in these topologies is the output inductor. To ensure robustness and meet customer requirements, designers typically specify a wide acceptable inductance range, ensuring correct system operation regardless of the specific inductor value chosen by the customer. However, this generally results in non-optimal performance in many cases. The compensation network must guarantee stability across the entire inductance range, often limiting maximum bandwidth and dynamic response because it is optimized for the worst-case scenario rather than actual component values. Consequently, the compromise required to ensure stability and compliance with specifications under critical conditions makes it impossible to optimize performance for all accepted component value combinations. Therefore, converters may suffer from reduced efficiency, as control parameters cannot be optimized for the specific inductance present in the final assembly. Another example of a non optimized parameter is the minimum on-time, which is typically limited conservatively by the worst-case inductance to control output voltage ripple. This imposes unnecessary efficiency losses when higher-value inductors are installed. To overcome these limitations, this thesis proposes an on-board output inductance estimation technique. The primary objective is to enable a more flexible and robust converter design by measuring the actual output inductance during the startup phase. The proposed architecture integrates an Inductor Current Emulator, which estimates inductor current dynamics, along with a High-Side current comparator. By comparing the actual current slope with the emulated reference, the system identifies the inductance threshold in real time. Measuring the output inductance enables several advantages. First, it allows for adaptive compensation of the control loop, maximizing performance and stability across different component selections. Second, it enables adaptive adjustment of the minimum on-time, improving efficiency at light loads when higher-value inductors are used. Third, it enhances system safety by verifying that the output inductance is within acceptable operational ranges during startup, inhibiting switching if components are out of specification. Finally, this approach can expand the functional range of the BOM (Bill of Materials), giving customers greater freedom in component selection while maintaining optimal performance. The analysis and simulations were performed using the Cadence Virtuoso design environment. The results validate the accuracy and robustness of the estimation.| File | Dimensione | Formato | |
|---|---|---|---|
|
Brandalese_Fabio.pdf
embargo fino al 30/09/2029
Dimensione
35.9 MB
Formato
Adobe PDF
|
35.9 MB | Adobe PDF |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/116029