The power grid is experiencing an increasing density of power electronics converters due to the integration of renewable sources. While traditional voltage and frequency stability remain critical, there is growing concern regarding converter-driven oscillations in the sub-kHz range. Currently, converter controllers are often tuned relying solely on the Short Circuit Ratio (SCR) and X/R ratio at the point of connection, which is insufficient for reliable frequency analysis. This document highlights the importance of accurate grid modeling and extracts relevant information through small-signal analysis. A converter state-space model is evaluated across increasingly complex case studies. First, a Thevenin equivalent grid is analyzed to assess varying grid strengths and highlight the model’s limitations at non-fundamental frequencies. Second, a configuration combining a Thevenin equivalent in parallel with a second vendor converter is investigated to demonstrate converter-driven oscillations not captured by the simple case. Finally, a system identification method: vector fitting is investigated to replicate unknown grids and perform small-signal analysis using only frequency scan data. The method is validated on the previous cases, and is applied to a modified IEEE 9-bus system.
L'integrazione delle fonti rinnovabili sta portando a una densità sempre maggiore di convertitori di potenza all'interno della rete elettrica. Sebbene lo studio di stabilità tradizionale di tensione e frequenza rimanga fondamentale, vi è una crescente preoccupazione per le oscillazioni indotte dai convertitori nel range dei sub-kHz. Attualmente, i controllori dei convertitori vengono spesso calibrati basandosi esclusivamente sul Short Circuit Ratio (SCR) e sul rapporto X/R nel punto di connessione, il che risulta insufficiente per un'analisi in frequenza affidabile. Questo documento evidenzia l'importanza di una modellazione accurata della rete ed estrae le informazioni rilevanti attraverso un'analisi a piccolo segnale. Un modello state-space del convertitore viene analizzato attraverso casi di studio di complessità crescente. In primo luogo, viene studiata una rete equivalente di Thevenin per valutare diverse robustezze della rete ed evidenziare i limiti del modello a frequenze non fondamentali. Successivamente, viene esaminata una configurazione che combina una rete equivalente di Thevenin in parallelo con un secondo convertitore, per dimostrare le oscillazioni indotte dai convertitori che non vengono colte dal caso più semplice. Infine, viene studiato un metodo di identificazione dei sistemi (il vector fitting) per replicare reti sconosciute ed eseguire l'analisi a piccolo segnale utilizzando unicamente i dati di scansione in frequenza. Il metodo, validato sui casi precedenti, viene applicato al sistema: IEEE 9-bus, appositamente modificato.
Impedance-based small-signal stability analysis of converter-based power systems
MAGAGNA, ALBERTO
2025/2026
Abstract
The power grid is experiencing an increasing density of power electronics converters due to the integration of renewable sources. While traditional voltage and frequency stability remain critical, there is growing concern regarding converter-driven oscillations in the sub-kHz range. Currently, converter controllers are often tuned relying solely on the Short Circuit Ratio (SCR) and X/R ratio at the point of connection, which is insufficient for reliable frequency analysis. This document highlights the importance of accurate grid modeling and extracts relevant information through small-signal analysis. A converter state-space model is evaluated across increasingly complex case studies. First, a Thevenin equivalent grid is analyzed to assess varying grid strengths and highlight the model’s limitations at non-fundamental frequencies. Second, a configuration combining a Thevenin equivalent in parallel with a second vendor converter is investigated to demonstrate converter-driven oscillations not captured by the simple case. Finally, a system identification method: vector fitting is investigated to replicate unknown grids and perform small-signal analysis using only frequency scan data. The method is validated on the previous cases, and is applied to a modified IEEE 9-bus system.| File | Dimensione | Formato | |
|---|---|---|---|
|
Alberto_Magagna_Master_Thesis.pdf
accesso aperto
Dimensione
2.54 MB
Formato
Adobe PDF
|
2.54 MB | Adobe PDF | Visualizza/Apri |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/116094