This thesis presents the design and implementation of an automated testbench for the char acterization of Hamamatsu R878 photomultiplier tubes (PMTs). These devices are used in a cosmic-ray neutron probe for soil-moisture monitoring, where they convert the weak optical signals produced by a scintillator into measurable electrical pulses. Due to manufacturing vari ability, nominally identical PMTs can exhibit different responses when operated at the same supply voltage, making individual characterization necessary before their integration into the final detector. The developed testbench uses a custom pulsed LED as a controlled optical source and mea sures the response of each PMT while automatically varying its high-voltage supply, allowing its characteristic response curve to be reconstructed. Since the optical output of the LED source cannot be characterized with sufficient accuracy, estimating the absolute PMT gain remains dif ficult. The adopted approach therefore uses the curve of a validated reference PMT as a base line. The curves obtained from the other devices are compared with this reference to identify anomalous units and determine the operating voltage required to reproduce the same response level. The resulting data provide a reproducible basis for component screening, estimated-gain equalization, voltage selection, and traceability throughout the detector production process. The completed system was applied to multiple R878 PMTs. An initial group of four tubes was measured through three consecutive voltage sweeps to evaluate testbench stability and re peatability. The repeated curves showed close agreement, while the coefficient of variation of the acquired pulse amplitudes remained below 2% for every tested device and operating point. A separate campaign involving ten additional PMTs revealed distinct groups of estimated gain voltage curves under identical measurement conditions, further confirming the need for individ ual characterization and voltage selection.

Design and Implementation of a Measurement Setup for the Characterization of Photomultiplier Tubes

MAZZON, LORENZO
2025/2026

Abstract

This thesis presents the design and implementation of an automated testbench for the char acterization of Hamamatsu R878 photomultiplier tubes (PMTs). These devices are used in a cosmic-ray neutron probe for soil-moisture monitoring, where they convert the weak optical signals produced by a scintillator into measurable electrical pulses. Due to manufacturing vari ability, nominally identical PMTs can exhibit different responses when operated at the same supply voltage, making individual characterization necessary before their integration into the final detector. The developed testbench uses a custom pulsed LED as a controlled optical source and mea sures the response of each PMT while automatically varying its high-voltage supply, allowing its characteristic response curve to be reconstructed. Since the optical output of the LED source cannot be characterized with sufficient accuracy, estimating the absolute PMT gain remains dif ficult. The adopted approach therefore uses the curve of a validated reference PMT as a base line. The curves obtained from the other devices are compared with this reference to identify anomalous units and determine the operating voltage required to reproduce the same response level. The resulting data provide a reproducible basis for component screening, estimated-gain equalization, voltage selection, and traceability throughout the detector production process. The completed system was applied to multiple R878 PMTs. An initial group of four tubes was measured through three consecutive voltage sweeps to evaluate testbench stability and re peatability. The repeated curves showed close agreement, while the coefficient of variation of the acquired pulse amplitudes remained below 2% for every tested device and operating point. A separate campaign involving ten additional PMTs revealed distinct groups of estimated gain voltage curves under identical measurement conditions, further confirming the need for individ ual characterization and voltage selection.
2025
Design and Implementation of a Measurement Setup for the Characterization of Photomultiplier Tubes
Testbench
Photomultiplier Tube
Gain
File in questo prodotto:
File Dimensione Formato  
Mazzon_Lorenzo.pdf

embargo fino al 07/10/2027

Dimensione 36.77 MB
Formato Adobe PDF
36.77 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/116324