Concentrated Solar Power (CSP) systems require highly reliable and precise temperature monitoring under extreme thermal conditions to optimize energy efficiency and ensure structural safety. Traditional sensors often fail to withstand these harsh environments, driving the need for advanced optical sensing solutions. This thesis presents a comprehensive experimental performance comparison between two prominent high-temperature sensor technologies: Femtosecond Fiber Bragg Gratings (fs-FBGs) and Regenerated Fiber Bragg Gratings (RFBGs). The research methodology encompasses the spectral planning, design validation, and experimental characterization of both sensor types. A systematic testing campaign was conducted at the CITIUS facility to evaluate their performance. Experimental calibration curves were established in the laboratory and compared against manufacturer datasheets to assess accuracy, precision, and deviation. Furthermore, both technologies were subjected to rigorous comparative evaluations focusing on critical performance indicators, including maximum operating temperature range, dynamic response, precision, and long-term thermal stability. The experimental results highlight the distinctive physical behaviors, strengths, and operational limitations of fs-FBG and RFBG sensors. This comparative analysis provides essential guidelines for selecting the optimal optical fiber sensing technology for extreme-temperature applications in next-generation solar thermal plants.
Concentrated Solar Power (CSP) systems require highly reliable and precise temperature monitoring under extreme thermal conditions to optimize energy efficiency and ensure structural safety. Traditional sensors often fail to withstand these harsh environments, driving the need for advanced optical sensing solutions. This thesis presents a comprehensive experimental performance comparison between two prominent high-temperature sensor technologies: Femtosecond Fiber Bragg Gratings (fs-FBGs) and Regenerated Fiber Bragg Gratings (RFBGs). The research methodology encompasses the spectral planning, design validation, and experimental characterization of both sensor types. A systematic testing campaign was conducted at the CITIUS facility to evaluate their performance. Experimental calibration curves were established in the laboratory and compared against manufacturer datasheets to assess accuracy, precision, and deviation. Furthermore, both technologies were subjected to rigorous comparative evaluations focusing on critical performance indicators, including maximum operating temperature range, dynamic response, precision, and long-term thermal stability. The experimental results highlight the distinctive physical behaviors, strengths, and operational limitations of fs-FBG and RFBG sensors. This comparative analysis provides essential guidelines for selecting the optimal optical fiber sensing technology for extreme-temperature applications in next-generation solar thermal plants.
Experimental Performance Comparison of Femtosecond and Regenerated Fiber Bragg Grating Sensors for High-Temperature Measurements in Concentrated Solar Power Applications
MALEKPOOR, REZA
2025/2026
Abstract
Concentrated Solar Power (CSP) systems require highly reliable and precise temperature monitoring under extreme thermal conditions to optimize energy efficiency and ensure structural safety. Traditional sensors often fail to withstand these harsh environments, driving the need for advanced optical sensing solutions. This thesis presents a comprehensive experimental performance comparison between two prominent high-temperature sensor technologies: Femtosecond Fiber Bragg Gratings (fs-FBGs) and Regenerated Fiber Bragg Gratings (RFBGs). The research methodology encompasses the spectral planning, design validation, and experimental characterization of both sensor types. A systematic testing campaign was conducted at the CITIUS facility to evaluate their performance. Experimental calibration curves were established in the laboratory and compared against manufacturer datasheets to assess accuracy, precision, and deviation. Furthermore, both technologies were subjected to rigorous comparative evaluations focusing on critical performance indicators, including maximum operating temperature range, dynamic response, precision, and long-term thermal stability. The experimental results highlight the distinctive physical behaviors, strengths, and operational limitations of fs-FBG and RFBG sensors. This comparative analysis provides essential guidelines for selecting the optimal optical fiber sensing technology for extreme-temperature applications in next-generation solar thermal plants.| File | Dimensione | Formato | |
|---|---|---|---|
|
Malekpoor_Reza.pdf
accesso aperto
Dimensione
4.29 MB
Formato
Adobe PDF
|
4.29 MB | Adobe PDF | Visualizza/Apri |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/116600