Limb-salvage surgery is the standard treatment for distal femoral osteosarcoma and involves tumour resection followed by reconstruction using a prosthetic implant. In paediatric patients, reconstruction is particularly challenging because skeletal growth and the age-dependent mechanical properties of paediatric bone strongly influence load transfer between the bone and the implant. The implant is typically fixed to the residual femur with a plate, an intramedullary stem, or a combination of both. Plates can be single or double, while stems can be straight or anatomical. Since the fixation strategy plays a key role in implant stability and long-term bone health, this finite element (FE) study compared different fixation techniques for a paediatric femoral implant following distal femoral resection. Their biomechanical behaviour was evaluated under different physiological loading conditions, together with their ability to reproduce the load transfer observed in the native femur. A patient-specific FE model of a 10-year-old femur was developed. Five configurations were analysed: a lateral plate, a double plate, a straight stem, an anatomical stem, and a combined stem–plate configuration. An additional shortened straight stem was modelled to assess the influence of stem length. Materials were considered homogeneous, isotropic, and linearly elastic. Axial, anteroposterior (AP), lateromedial (LM), torsional, and sideways-fall load cases were simulated. Loads were scaled from adult reference data using a paediatric factor of 0.52. Axial and shear stresses were averaged within five anatomical regions along the femur. None of the configurations reproduced the native response under all loading conditions, and their performance depended on fixation type and stem length. Under axial loading, the native femur exhibited low and uniform compressive stresses throughout the diaphysis, whereas all implant configurations generated proximal stress concentrations. The double plate also caused marked distal stress shielding. Under AP, LM, and sideways-fall loading, the plate configurations produced stress concentrations around the most proximal screw and substantial distal stress shielding. The standard straight stem was excessively long and stiff for the paediatric femur and, particularly under sideways-fall loading, carried a large proportion of the applied load, producing widespread stress shielding. The anatomical stem improved this response by following the femoral curvature. However, the shortened straight stem achieved comparable or better results across the investigated load cases with a simpler geometry. It transferred more load to the cortical bone and produced stresses closer to native values without compromising the axial response. Under torsion, the stems reduced shear stresses in the distal and mid-diaphyseal regions, whereas the double plate produced the highest peaks. The combined stem–plate configuration provided no clear mechanical advantage. Fracture risk and micromotion remained below the thresholds adopted from the literature. These findings demonstrate that fixation type and, particularly, stem length and geometry strongly influence load transfer following paediatric distal femoral reconstruction. The biomechanical limitations observed with the straight stem were primarily related to its adult-derived length, which transferred an excessive proportion of the load away from the immature femur, rather than to the fixation concept itself. Among the configurations investigated, the shortened stem provided the best biomechanical compromise, reducing stress shielding while maintaining fixation stability. Patient-specific design should therefore include optimisation of implant geometry to promote more physiological load transfer and potentially improve the durability of the reconstruction.

La chirurgia di salvataggio d'arto è il trattamento standard dell'osteosarcoma del femore distale e prevede la resezione del tumore seguita da ricostruzione con impianto protesico. Nel paziente pediatrico la ricostruzione è particolarmente complessa, poiché la crescita scheletrica e le proprietà meccaniche dell'osso, variabili con l'età, influenzano il trasferimento del carico tra osso e impianto. L'impianto generalmente viene fissato al femore residuo con una placca (singola o doppia), uno stelo endomidollare (dritto o anatomico) o entrambi. Poiché il tipo di fissaggio è determinante per la stabilità dell'impianto e la salute ossea a lungo termine, questo studio agli elementi finiti (FE) ha confrontato diverse tecniche di fissaggio per un impianto femorale pediatrico dopo resezione distale. Sono stati valutati il comportamento biomeccanico in diverse condizioni di carico fisiologico e la capacità di riprodurre il trasferimento del carico del femore nativo. È stato sviluppato un modello FE paziente-specifico del femore di un bambino di 10 anni. Sono state analizzate cinque configurazioni: placca laterale, doppia placca, stelo dritto, stelo anatomico e configurazione combinata stelo-placca. È stato inoltre modellato uno stelo dritto accorciato per valutare l'influenza della lunghezza dello stelo. I materiali sono stati considerati omogenei, isotropi e linearmente elastici. Sono stati simulati carichi assiali, antero-posteriori (AP), latero-mediali (LM), torsionali e di caduta laterale. I carichi sono stati scalati da dati di riferimento per l'adulto con un fattore pediatrico di 0,52. Le tensioni assiali e di taglio sono state mediate in cinque regioni anatomiche lungo il femore. Nessuna configurazione ha riprodotto la risposta nativa in tutte le condizioni di carico; le prestazioni dipendevano dal tipo di fissaggio e dalla lunghezza dello stelo. In carico assiale, il femore nativo mostrava tensioni di compressione basse e uniformi lungo tutta la diafisi, mentre tutte le configurazioni protesiche generavano concentrazioni di tensione prossimali. La doppia placca causava inoltre un marcato stress shielding distale. Nei carichi AP, LM e caduta laterale, le placche producevano concentrazioni di tensione attorno alla vite più prossimale e un consistente stress shielding distale. Lo stelo dritto standard è risultato troppo lungo e rigido per il femore pediatrico e, soprattutto in caduta laterale, assorbiva gran parte del carico applicato, determinando uno stress shielding diffuso. Lo stelo anatomico migliorava questa risposta seguendo la curvatura femorale. Tuttavia, lo stelo dritto accorciato ha ottenuto risultati comparabili o migliori in tutti i casi di carico con una geometria più semplice, trasferendo più carico all'osso corticale e producendo tensioni più vicine ai valori nativi, senza compromettere la risposta assiale. In torsione, gli steli riducevano le tensioni di taglio nelle regioni distale e mediodiafisaria, mentre la doppia placca produceva i picchi più elevati. La configurazione stelo-placca non ha mostrato vantaggi meccanici evidenti. Rischio di frattura e micromovimenti sono rimasti sotto le soglie adottate dalla letteratura. Questi risultati dimostrano che il tipo di fissaggio e la sua geometria influenzano fortemente il trasferimento del carico. Le limitazioni biomeccaniche osservate con lo stelo dritto erano principalmente riconducibili alle sue dimensioni, definite a partire dalla geometria di una protesi per adulti, che trasferiva una proporzione eccessiva del carico lontano dal femore. Tra le configurazioni investigate, lo stelo accorciato ha fornito il miglior compromesso biomeccanico, riducendo lo stress shielding pur mantenendo la stabilità del fissaggio. La progettazione paziente-specifica dovrebbe pertanto includere l'ottimizzazione della geometria dell'impianto per promuovere un trasferimento del carico più fisiologico e potenzialmente migliorare la durabilità della ricostruzione.

Biomechanical analysis of different fixation techniques in pediatric femoral implants for osteosarcoma

ROS, PAOLA
2025/2026

Abstract

Limb-salvage surgery is the standard treatment for distal femoral osteosarcoma and involves tumour resection followed by reconstruction using a prosthetic implant. In paediatric patients, reconstruction is particularly challenging because skeletal growth and the age-dependent mechanical properties of paediatric bone strongly influence load transfer between the bone and the implant. The implant is typically fixed to the residual femur with a plate, an intramedullary stem, or a combination of both. Plates can be single or double, while stems can be straight or anatomical. Since the fixation strategy plays a key role in implant stability and long-term bone health, this finite element (FE) study compared different fixation techniques for a paediatric femoral implant following distal femoral resection. Their biomechanical behaviour was evaluated under different physiological loading conditions, together with their ability to reproduce the load transfer observed in the native femur. A patient-specific FE model of a 10-year-old femur was developed. Five configurations were analysed: a lateral plate, a double plate, a straight stem, an anatomical stem, and a combined stem–plate configuration. An additional shortened straight stem was modelled to assess the influence of stem length. Materials were considered homogeneous, isotropic, and linearly elastic. Axial, anteroposterior (AP), lateromedial (LM), torsional, and sideways-fall load cases were simulated. Loads were scaled from adult reference data using a paediatric factor of 0.52. Axial and shear stresses were averaged within five anatomical regions along the femur. None of the configurations reproduced the native response under all loading conditions, and their performance depended on fixation type and stem length. Under axial loading, the native femur exhibited low and uniform compressive stresses throughout the diaphysis, whereas all implant configurations generated proximal stress concentrations. The double plate also caused marked distal stress shielding. Under AP, LM, and sideways-fall loading, the plate configurations produced stress concentrations around the most proximal screw and substantial distal stress shielding. The standard straight stem was excessively long and stiff for the paediatric femur and, particularly under sideways-fall loading, carried a large proportion of the applied load, producing widespread stress shielding. The anatomical stem improved this response by following the femoral curvature. However, the shortened straight stem achieved comparable or better results across the investigated load cases with a simpler geometry. It transferred more load to the cortical bone and produced stresses closer to native values without compromising the axial response. Under torsion, the stems reduced shear stresses in the distal and mid-diaphyseal regions, whereas the double plate produced the highest peaks. The combined stem–plate configuration provided no clear mechanical advantage. Fracture risk and micromotion remained below the thresholds adopted from the literature. These findings demonstrate that fixation type and, particularly, stem length and geometry strongly influence load transfer following paediatric distal femoral reconstruction. The biomechanical limitations observed with the straight stem were primarily related to its adult-derived length, which transferred an excessive proportion of the load away from the immature femur, rather than to the fixation concept itself. Among the configurations investigated, the shortened stem provided the best biomechanical compromise, reducing stress shielding while maintaining fixation stability. Patient-specific design should therefore include optimisation of implant geometry to promote more physiological load transfer and potentially improve the durability of the reconstruction.
2025
Biomechanical analysis of different fixation techniques in pediatric femoral implants for osteosarcoma
La chirurgia di salvataggio d'arto è il trattamento standard dell'osteosarcoma del femore distale e prevede la resezione del tumore seguita da ricostruzione con impianto protesico. Nel paziente pediatrico la ricostruzione è particolarmente complessa, poiché la crescita scheletrica e le proprietà meccaniche dell'osso, variabili con l'età, influenzano il trasferimento del carico tra osso e impianto. L'impianto generalmente viene fissato al femore residuo con una placca (singola o doppia), uno stelo endomidollare (dritto o anatomico) o entrambi. Poiché il tipo di fissaggio è determinante per la stabilità dell'impianto e la salute ossea a lungo termine, questo studio agli elementi finiti (FE) ha confrontato diverse tecniche di fissaggio per un impianto femorale pediatrico dopo resezione distale. Sono stati valutati il comportamento biomeccanico in diverse condizioni di carico fisiologico e la capacità di riprodurre il trasferimento del carico del femore nativo. È stato sviluppato un modello FE paziente-specifico del femore di un bambino di 10 anni. Sono state analizzate cinque configurazioni: placca laterale, doppia placca, stelo dritto, stelo anatomico e configurazione combinata stelo-placca. È stato inoltre modellato uno stelo dritto accorciato per valutare l'influenza della lunghezza dello stelo. I materiali sono stati considerati omogenei, isotropi e linearmente elastici. Sono stati simulati carichi assiali, antero-posteriori (AP), latero-mediali (LM), torsionali e di caduta laterale. I carichi sono stati scalati da dati di riferimento per l'adulto con un fattore pediatrico di 0,52. Le tensioni assiali e di taglio sono state mediate in cinque regioni anatomiche lungo il femore. Nessuna configurazione ha riprodotto la risposta nativa in tutte le condizioni di carico; le prestazioni dipendevano dal tipo di fissaggio e dalla lunghezza dello stelo. In carico assiale, il femore nativo mostrava tensioni di compressione basse e uniformi lungo tutta la diafisi, mentre tutte le configurazioni protesiche generavano concentrazioni di tensione prossimali. La doppia placca causava inoltre un marcato stress shielding distale. Nei carichi AP, LM e caduta laterale, le placche producevano concentrazioni di tensione attorno alla vite più prossimale e un consistente stress shielding distale. Lo stelo dritto standard è risultato troppo lungo e rigido per il femore pediatrico e, soprattutto in caduta laterale, assorbiva gran parte del carico applicato, determinando uno stress shielding diffuso. Lo stelo anatomico migliorava questa risposta seguendo la curvatura femorale. Tuttavia, lo stelo dritto accorciato ha ottenuto risultati comparabili o migliori in tutti i casi di carico con una geometria più semplice, trasferendo più carico all'osso corticale e producendo tensioni più vicine ai valori nativi, senza compromettere la risposta assiale. In torsione, gli steli riducevano le tensioni di taglio nelle regioni distale e mediodiafisaria, mentre la doppia placca produceva i picchi più elevati. La configurazione stelo-placca non ha mostrato vantaggi meccanici evidenti. Rischio di frattura e micromovimenti sono rimasti sotto le soglie adottate dalla letteratura. Questi risultati dimostrano che il tipo di fissaggio e la sua geometria influenzano fortemente il trasferimento del carico. Le limitazioni biomeccaniche osservate con lo stelo dritto erano principalmente riconducibili alle sue dimensioni, definite a partire dalla geometria di una protesi per adulti, che trasferiva una proporzione eccessiva del carico lontano dal femore. Tra le configurazioni investigate, lo stelo accorciato ha fornito il miglior compromesso biomeccanico, riducendo lo stress shielding pur mantenendo la stabilità del fissaggio. La progettazione paziente-specifica dovrebbe pertanto includere l'ottimizzazione della geometria dell'impianto per promuovere un trasferimento del carico più fisiologico e potenzialmente migliorare la durabilità della ricostruzione.
Chirurgia ortopedica
Modellazione FEM
Fissaggio protesi
File in questo prodotto:
File Dimensione Formato  
ROS_PAOLA.pdf

embargo fino al 06/10/2027

Dimensione 5.29 MB
Formato Adobe PDF
5.29 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/116615