Design of an acquisition system that allow to collect data about the load acting at the foot clamp of the prosthetic foot during running. The in-vitro calibration of the system was performed with a test bench, instead, the validation was performed in two different ways: in-vitro validation and in-vivo validation, with the runs of the athletes. One athlete have a transtibial amputation and the other a transfemoral amputation. The data obtained are then compared with data of a forceplate.
Structural analysis and functional behaviour of Running Specific Prosthesis during in-vivo field tests and laboratory bench tests
Foscan, Gianmario
2018/2019
Abstract
Design of an acquisition system that allow to collect data about the load acting at the foot clamp of the prosthetic foot during running. The in-vitro calibration of the system was performed with a test bench, instead, the validation was performed in two different ways: in-vitro validation and in-vivo validation, with the runs of the athletes. One athlete have a transtibial amputation and the other a transfemoral amputation. The data obtained are then compared with data of a forceplate.File in questo prodotto: