In this thesis the results and the experimental measurement procedures for the calculation of the local exchange coefficients of a brazed plate heat exchanger are presented. The fluids used were R404A, R290 (propane) and R1270 (propylene). The coefficients were obtained both in condensation and in vaporization, at a saturation temperature of 30 ° C and 10 ° C respectively and at different flow rates. The system used is equipped with a test section specially designed for the placement of thermocouples along the fluid channel. The experimental results obtained were compared against theoretical models.
In questa tesi vengono esposti i risultati e le procedure di misure sperimentali per il calcolo dei coefficienti di scambio locali di uno scambiatore a piastre saldobrasate. I fluidi utilizzati sono stati l'R404A, l'R290 (propano) e l'R1270 (propilene). I coefficienti sono stati ricavati sia in condensazione che in vaporizzazione, a una temperatura di saturazione rispettivamente di 30°C e 10°C e a differenti portate. L'impianto utilizzato è dotato di una sezione di prova appositamente progettata per il posizionamento di termocoppie lungo il canale del fluido. I risultati sperimentali ottenuti sono stati confrontati con modelli teorici.
Misura sperimentale dei coefficienti di scambio termico locale nella condensazione e vaporizzazione di R404A, R290(Propano) ed R1270(Propilene) in uno scambiatore di calore a piastre saldobrasate
CONTE, FRANCESCO
2021/2022
Abstract
In this thesis the results and the experimental measurement procedures for the calculation of the local exchange coefficients of a brazed plate heat exchanger are presented. The fluids used were R404A, R290 (propane) and R1270 (propylene). The coefficients were obtained both in condensation and in vaporization, at a saturation temperature of 30 ° C and 10 ° C respectively and at different flow rates. The system used is equipped with a test section specially designed for the placement of thermocouples along the fluid channel. The experimental results obtained were compared against theoretical models.File | Dimensione | Formato | |
---|---|---|---|
Conte_Francesco.pdf
accesso aperto
Dimensione
10.08 MB
Formato
Adobe PDF
|
10.08 MB | Adobe PDF | Visualizza/Apri |