The thesis is part of a series of activities aimed at validating a mathematical model in vivo and then on patient of aortic stenosis severity implementable in echodoppler, in particular the thesis deals with the evaluation of the instantaneous trend of the Effective Orifice Area (EOA) with particular attention to possible sources of error: the variability of the left ventricular outflow tract is considered in terms of time (systolic period of the cardiac cycle evaluating the diversity according to whether it is early-systolic, mid-systolic or tele-systolic), ellipticity and position (different positions used for measurement result in different EOA values). The evaluations are derived from measurements on five patients with congenital aortic stenosis.

Il lavoro di tesi fa parte di una serie di attività volte a validare in vivo e quindi su paziente un modello matematico di severità della stenosi aortica implementabile in ecodoppler, in particolare la tesi si occupa della valutazione dell’andamento istantaneo dell’Area Orifiziale Effettiva (EOA) con particolare attenzione alle possibili fonti di errore: si considera la variabilità del tratto di efflusso del ventricolo sinistro in termini di tempo (periodo sistolico del ciclo cardiaco valutando la diversità a seconda se si tratta del precoce-sistolico, medio-sistolico o tele-sistolico), ellitticità e posizione (diverse posizioni usate per la misura comportano valori dell’EOA differenti). Le valutazioni sono fatte partendo da misure su cinque pazienti con stenosi aortica congenita.

Dinamica dell’area orifiziale effettiva nella stenosi valvolare aortica congenita

BONARDI, CORINNE
2022/2023

Abstract

The thesis is part of a series of activities aimed at validating a mathematical model in vivo and then on patient of aortic stenosis severity implementable in echodoppler, in particular the thesis deals with the evaluation of the instantaneous trend of the Effective Orifice Area (EOA) with particular attention to possible sources of error: the variability of the left ventricular outflow tract is considered in terms of time (systolic period of the cardiac cycle evaluating the diversity according to whether it is early-systolic, mid-systolic or tele-systolic), ellipticity and position (different positions used for measurement result in different EOA values). The evaluations are derived from measurements on five patients with congenital aortic stenosis.
2022
Dynamics of the effective orifice area in congenital aortic valve stenosis
Il lavoro di tesi fa parte di una serie di attività volte a validare in vivo e quindi su paziente un modello matematico di severità della stenosi aortica implementabile in ecodoppler, in particolare la tesi si occupa della valutazione dell’andamento istantaneo dell’Area Orifiziale Effettiva (EOA) con particolare attenzione alle possibili fonti di errore: si considera la variabilità del tratto di efflusso del ventricolo sinistro in termini di tempo (periodo sistolico del ciclo cardiaco valutando la diversità a seconda se si tratta del precoce-sistolico, medio-sistolico o tele-sistolico), ellitticità e posizione (diverse posizioni usate per la misura comportano valori dell’EOA differenti). Le valutazioni sono fatte partendo da misure su cinque pazienti con stenosi aortica congenita.
EOA
Stenosi aortica
Variabilità esiti
File in questo prodotto:
File Dimensione Formato  
Bonardi_Corinne.pdf

accesso aperto

Dimensione 4.72 MB
Formato Adobe PDF
4.72 MB Adobe PDF Visualizza/Apri

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/43314