In the cardiovascular context, the replacement of damaged vascular segments requires advanced solutions capable of overcoming the durability and reliability limitations of current synthetic and biological grafts. A promising alternative is represented by the use of hybrid materials, obtained by coupling decellularized biological tissue with a synthetic polymer, in order to maintain adequate characteristics of hemocompatibility, impermeability, and mechanical strength. This study aims to mechanically characterize the tubular conduit composed of decellularized porcine pericardium coupled with Chronoflex AR, a commercially available polycarbonate urethane. An additional aim is the preliminary assessment of the functionality of the construct obtained in anticipation of its application in the cardiovascular field.

Nel contesto cardiovascolare la sostituzione di segmenti vascolari danneggiati richiede soluzioni avanzate che possano superare i limiti di durata e affidabilità degli attuali innesti sintetici e biologici. Una promettente alternativa è rappresentata dall’impiego di materiali ibridi, ottenuti dall’accoppiamento di un tessuto biologico decellularizzato con un polimero sintetico, in modo tale da mantenere adeguate caratteristiche di emocompatibilità, di impermeabilità e di resistenza meccanica. Questo studio si propone di caratterizzare dal punto di vista meccanico il condotto tubulare costituito da pericardio porcino decellularizzato accoppiato al Chronoflex AR, un policarbonato uretano disponibile commercialmente. Un ulteriore obiettivo è dato dalla preliminare valutazione di funzionalità del costrutto ottenuto in previsione dell’applicazione in ambito cardiovascolare.

Produzione e caratterizzazione di una struttura tubulare ingegnerizzata per applicazioni in ambito cardiovascolare

ROMAGNOLI, PIER LUIGI
2023/2024

Abstract

In the cardiovascular context, the replacement of damaged vascular segments requires advanced solutions capable of overcoming the durability and reliability limitations of current synthetic and biological grafts. A promising alternative is represented by the use of hybrid materials, obtained by coupling decellularized biological tissue with a synthetic polymer, in order to maintain adequate characteristics of hemocompatibility, impermeability, and mechanical strength. This study aims to mechanically characterize the tubular conduit composed of decellularized porcine pericardium coupled with Chronoflex AR, a commercially available polycarbonate urethane. An additional aim is the preliminary assessment of the functionality of the construct obtained in anticipation of its application in the cardiovascular field.
2023
Production and characterization of an engineered tubular structure for cardiovascular applications
Nel contesto cardiovascolare la sostituzione di segmenti vascolari danneggiati richiede soluzioni avanzate che possano superare i limiti di durata e affidabilità degli attuali innesti sintetici e biologici. Una promettente alternativa è rappresentata dall’impiego di materiali ibridi, ottenuti dall’accoppiamento di un tessuto biologico decellularizzato con un polimero sintetico, in modo tale da mantenere adeguate caratteristiche di emocompatibilità, di impermeabilità e di resistenza meccanica. Questo studio si propone di caratterizzare dal punto di vista meccanico il condotto tubulare costituito da pericardio porcino decellularizzato accoppiato al Chronoflex AR, un policarbonato uretano disponibile commercialmente. Un ulteriore obiettivo è dato dalla preliminare valutazione di funzionalità del costrutto ottenuto in previsione dell’applicazione in ambito cardiovascolare.
Biomeccanica
Membrana ibrida
Chronoflex AR
Struttura tubulare
Tessuto DPP
File in questo prodotto:
File Dimensione Formato  
Romagnoli_PierLuigi.pdf

embargo fino al 23/04/2027

Dimensione 4.43 MB
Formato Adobe PDF
4.43 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/64999