The thesis focuses on a parametric analysis of the coefficients characterizing viscous damping devices and their effect when combined with a seismic isolation system. The main objective is to identify the optimal parameters of viscous dampers to maximize the benefits they can provide, both to the isolation system in terms of maximum displacement of the isolators and base shear, and to the superstructure in terms of interstory drift and floor accelerations. The reference model is an eleven-story reinforced concrete building subjected to a high-intensity earthquake. Given the highly nonlinear nature of the devices used, nonlinear dynamic analyses (Time History) were applied to realistically simulate their behavior. For this purpose, the SAP2000 software was used, which, thanks to the Fast Nonlinear Analysis capability, allows for a rapid and effective resolution of the case study. The results obtained highlight the importance of proper tuning of the parameters to significantly improve the seismic response of the structure.

La tesi ha come oggetto un'analisi parametrica dei coefficienti che caratterizzano i dispositivi di dissipazione viscosa e del loro effetto quando combinati con un sistema di isolamento sismico. L'obiettivo principale è identificare i parametri ottimali dei dissipatori viscosi per massimizzare il beneficio che possono dare sia al sistema di isolamento in termini di spostamento massimo degli isolatori e taglio alla base, sia alla sovrastruttura in termini di drift interpiano e accelerazioni di piano. Il modello di riferimento è un edificio in calcestruzzo armato di undici piani fuori terra, soggetto a un sisma di elevata intensità. Data la natura fortemente non lineare dei dispositivi utilizzati, sono state applicate analisi dinamiche non lineari (Time History) per simulare realisticamente il loro comportamento. A tale scopo è stato utilizzato il software SAP2000, che, grazie alla possibilità di utilizzare la Fast Nonlinear Analysis, consente una risoluzione rapida ed efficace del caso studio. I risultati ottenuti evidenziano l'importanza di una corretta taratura dei parametri per migliorare significativamente la risposta sismica della struttura.

Ottimizzazione dei parametri di dispositivi di dissipazione viscosa nella progettazione combinata con isolamento sismico

SCOLARI, FEDERICO
2023/2024

Abstract

The thesis focuses on a parametric analysis of the coefficients characterizing viscous damping devices and their effect when combined with a seismic isolation system. The main objective is to identify the optimal parameters of viscous dampers to maximize the benefits they can provide, both to the isolation system in terms of maximum displacement of the isolators and base shear, and to the superstructure in terms of interstory drift and floor accelerations. The reference model is an eleven-story reinforced concrete building subjected to a high-intensity earthquake. Given the highly nonlinear nature of the devices used, nonlinear dynamic analyses (Time History) were applied to realistically simulate their behavior. For this purpose, the SAP2000 software was used, which, thanks to the Fast Nonlinear Analysis capability, allows for a rapid and effective resolution of the case study. The results obtained highlight the importance of proper tuning of the parameters to significantly improve the seismic response of the structure.
2023
Optimization of viscous dissipation devices parameters in combined design with seismic isolation
La tesi ha come oggetto un'analisi parametrica dei coefficienti che caratterizzano i dispositivi di dissipazione viscosa e del loro effetto quando combinati con un sistema di isolamento sismico. L'obiettivo principale è identificare i parametri ottimali dei dissipatori viscosi per massimizzare il beneficio che possono dare sia al sistema di isolamento in termini di spostamento massimo degli isolatori e taglio alla base, sia alla sovrastruttura in termini di drift interpiano e accelerazioni di piano. Il modello di riferimento è un edificio in calcestruzzo armato di undici piani fuori terra, soggetto a un sisma di elevata intensità. Data la natura fortemente non lineare dei dispositivi utilizzati, sono state applicate analisi dinamiche non lineari (Time History) per simulare realisticamente il loro comportamento. A tale scopo è stato utilizzato il software SAP2000, che, grazie alla possibilità di utilizzare la Fast Nonlinear Analysis, consente una risoluzione rapida ed efficace del caso studio. I risultati ottenuti evidenziano l'importanza di una corretta taratura dei parametri per migliorare significativamente la risposta sismica della struttura.
Dissipatori viscosi
Isolamento sismico
Friction pendulum
Ottimizzazione
File in questo prodotto:
File Dimensione Formato  
Scolari_Federico.pdf

accesso riservato

Dimensione 14.67 MB
Formato Adobe PDF
14.67 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/69466