The Olivetti factories in Ivrea, a large complex of approximately 50,000 square meters, were built between 1930 and 1980. Currently, much of this complex is unused. This document proposes a preliminary dynamic energy analysis using the DesignBuilder software, based on the EnergyPlus engine, with the main objective of assessing current energy consumption and potential future energy and economic savings following the revamping. Among the various planned improvements, the addition of thermal insulation, window replacement, and the implementation of a new open-loop geothermal heating system are included. A comparison will be made between the current state of the building and its refurbished version. Additionally, other system solutions will be analyzed and their differences in terms of energy performance compared. The document will also describe the process of creating the energy model and the simplifications made to optimize the analysis, as the goal is to use dynamic analysis in a preliminary phase, when, however, the available information is limited.

Le officine Olivetti di Ivrea, un vasto complesso di circa 50.000 m², furono costruite tra il 1930 e il 1980. Attualmente, gran parte di questo complesso è in disuso. Il presente documento propone un'analisi energetica dinamica preliminare utilizzando il software DesignBuilder, basato sul motore di calcolo EnergyPlus, con l’obiettivo principale di valutare i consumi energetici attuali e i potenziali risparmi energetici ed economici futuri, in seguito al revamping. Tra le varie migliorie previste, sono incluse l'aggiunta di un cappotto termico, la sostituzione degli infissi e l'implementazione di un nuovo impianto termico basato su un sistema geotermico a ciclo aperto. Verrà quindi effettuato un confronto tra lo stato attuale dell'edificio e una sua versione riqualificata. Inoltre, saranno analizzate altre soluzioni impiantistiche e confrontate le differenze in termini di prestazioni energetiche. Il documento descriverà anche il processo di creazione del modello energetico e le semplificazioni adottate per ottimizzare l'analisi, poiché l'obiettivo è utilizzare l'analisi dinamica in una fase preliminare, quando però le informazioni disponibili sono limitate.

Dynamic energy simulation and feasibility study of the Olivetti factories in Ivrea.

VALCONI, JACOPO
2023/2024

Abstract

The Olivetti factories in Ivrea, a large complex of approximately 50,000 square meters, were built between 1930 and 1980. Currently, much of this complex is unused. This document proposes a preliminary dynamic energy analysis using the DesignBuilder software, based on the EnergyPlus engine, with the main objective of assessing current energy consumption and potential future energy and economic savings following the revamping. Among the various planned improvements, the addition of thermal insulation, window replacement, and the implementation of a new open-loop geothermal heating system are included. A comparison will be made between the current state of the building and its refurbished version. Additionally, other system solutions will be analyzed and their differences in terms of energy performance compared. The document will also describe the process of creating the energy model and the simplifications made to optimize the analysis, as the goal is to use dynamic analysis in a preliminary phase, when, however, the available information is limited.
2023
Dynamic energy simulation and feasibility study of the Olivetti factories in Ivrea.
Le officine Olivetti di Ivrea, un vasto complesso di circa 50.000 m², furono costruite tra il 1930 e il 1980. Attualmente, gran parte di questo complesso è in disuso. Il presente documento propone un'analisi energetica dinamica preliminare utilizzando il software DesignBuilder, basato sul motore di calcolo EnergyPlus, con l’obiettivo principale di valutare i consumi energetici attuali e i potenziali risparmi energetici ed economici futuri, in seguito al revamping. Tra le varie migliorie previste, sono incluse l'aggiunta di un cappotto termico, la sostituzione degli infissi e l'implementazione di un nuovo impianto termico basato su un sistema geotermico a ciclo aperto. Verrà quindi effettuato un confronto tra lo stato attuale dell'edificio e una sua versione riqualificata. Inoltre, saranno analizzate altre soluzioni impiantistiche e confrontate le differenze in termini di prestazioni energetiche. Il documento descriverà anche il processo di creazione del modello energetico e le semplificazioni adottate per ottimizzare l'analisi, poiché l'obiettivo è utilizzare l'analisi dinamica in una fase preliminare, quando però le informazioni disponibili sono limitate.
Dynamic simulation
Energy
Revamping
File in questo prodotto:
File Dimensione Formato  
Valconi_Jacopo.pdf

accesso riservato

Dimensione 14.48 MB
Formato Adobe PDF
14.48 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/78654