The present work analyzes the seismic response of a "Casa di Comunità" in reinforced concrete, located in Camisano Vicentino, equipped with seismic walls. The structure was designed following a non-dissipative criterion due to the considerable rigidity of the shear walls. A finite element model of the building was created, and to assess its seismic behavior, a linear dynamic analysis with a response spectrum and two nonlinear analyses were conducted to account for possible unforeseen nonlinear effects, specifically a static nonlinear analysis, "Pushover," and a dynamic nonlinear analysis, "Time-History." The static nonlinear analysis allowed for an initial evaluation of the structure's resistance capacity, providing a preliminary estimate of displacement demand and collapse mechanisms, while the dynamic nonlinear analysis, performed using artificial accelerograms, was used to compare the results with those from the linear dynamic analysis, as required by the NTC18 provisions. The comparison allowed for the evaluation of the validity of the "Time-History" as an effective alternative for the design of new structures, compared to the conventional analyses typically used. Furthermore, it confirmed that the shear walls provide significant structural rigidity, ensuring stability and limiting oscillations, allowing the structure to remain in the elastic range during the seismic event.
Il presente lavoro analizza la risposta sismica di una Casa di Comunità in cemento armato, situata a Camisano Vicentino, dotata di setti antisismici. La struttura è stata progettata seguendo un criterio non dissipativo, in ragione della notevole rigidezza dei setti tozzi. È stata effettuata la modellazione ad elementi finiti dell'edificio e, per valutarne il comportamento sismico, sono state condotte un'analisi dinamica lineare con spettro di risposta e due analisi non lineari per considerare eventuali effetti non lineari non previsti, cioè una statica non lineare,”Pushover” e una dinamica non lineare, “Time-History”. L'analisi statica non lineare ha permesso di ottenere una prima valutazione della capacità resistente della struttura consentendo di ottenere una prima stima della domanda di spostamento e delle modalità di collasso strutturale, mentre l'analisi dinamica non lineare, eseguita con accelerogrammi artificiali, è stata utilizzata per eseguire un confronto con le sollecitazioni derivanti dall’analisi dinamica lineare come richiesto dalle prescrizioni delle NTC18. Il confronto ha consentito di valutare la validità della “Time-History” come efficace alternativa per la progettazione di nuove strutture, rispetto alle consuete analisi utilizzate. Inoltre è servita a confermare che i setti tozzi conferiscono una sostanziale rigidezza strutturale, garantiscono stabilità e limitano le oscillazioni, consentendo alla struttura di rimanere in campo elastico durante l’evento sismico.
Valutazione della risposta sismica di un edificio a setti in calcestruzzo armato
CAPOZZA, BIANCA MARIA
2024/2025
Abstract
The present work analyzes the seismic response of a "Casa di Comunità" in reinforced concrete, located in Camisano Vicentino, equipped with seismic walls. The structure was designed following a non-dissipative criterion due to the considerable rigidity of the shear walls. A finite element model of the building was created, and to assess its seismic behavior, a linear dynamic analysis with a response spectrum and two nonlinear analyses were conducted to account for possible unforeseen nonlinear effects, specifically a static nonlinear analysis, "Pushover," and a dynamic nonlinear analysis, "Time-History." The static nonlinear analysis allowed for an initial evaluation of the structure's resistance capacity, providing a preliminary estimate of displacement demand and collapse mechanisms, while the dynamic nonlinear analysis, performed using artificial accelerograms, was used to compare the results with those from the linear dynamic analysis, as required by the NTC18 provisions. The comparison allowed for the evaluation of the validity of the "Time-History" as an effective alternative for the design of new structures, compared to the conventional analyses typically used. Furthermore, it confirmed that the shear walls provide significant structural rigidity, ensuring stability and limiting oscillations, allowing the structure to remain in the elastic range during the seismic event.| File | Dimensione | Formato | |
|---|---|---|---|
|
Capozza_BiancaMaria.pdf
Accesso riservato
Dimensione
10.59 MB
Formato
Adobe PDF
|
10.59 MB | Adobe PDF |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/85315