Starting from a transmission line model with uniformly distributed parameters, this thesis aims to develop an analytical formulation for the optimization of long High Voltage Alternating Current (HVAC) cable connections. The objective is to estimate the maximum transmittable power through HVAC cables under both nominal and optimized conditions. To this end, the developed procedure determines the optimal operating voltage as a function of the cable length in order to reduce the reactive power demand and maximize the transmitted power. The proposed approach has been compared with other methods in the literature based on lumped parameter models, as well as with the Ossanna method for transmission line modeling. The accuracy of the developed procedure proves to be satisfactory, particularly in relation to its ease of application
La tesi, partendo da un modello di linea a parametri uniformemente distribuiti, si pone l'obiettivo di individuare una formulazione analitica per l’ottimizzazione di lunghi collegamenti in cavo in alta tensione in corrente alternata (HVAC). L’obiettivo è quello di stimare la massima potenza trasmissibile da cavi HVAC sia in condizioni nominali, sia in condizioni ottimizzate. A tal fine la procedura sviluppata è in grado di determinare qual è la tensione d’esercizio ottimale in funzione della lunghezza del collegamento per ridurre la potenza reattiva richiesta dal cavo e massimizzare la potenza trasmessa. L'approccio sviluppato è stato confrontato sia con altre metodologie presenti in letteratura basate su modelli a parametri concentrati, sia con il metodo di Ossanna per la modellizzazione di linea di trasmissione. La precisione della procedura ottenuta risulta soddisfacente, soprattutto in relazione alla sua semplicità di applicazione
Sviluppo di un metodo analitico a parametri uniformemente distribuiti per l’ottimizzazione di lunghi collegamenti in cavo in alta tensione in corrente alternata
RAVAZZOLO, MARCO TULLIO
2024/2025
Abstract
Starting from a transmission line model with uniformly distributed parameters, this thesis aims to develop an analytical formulation for the optimization of long High Voltage Alternating Current (HVAC) cable connections. The objective is to estimate the maximum transmittable power through HVAC cables under both nominal and optimized conditions. To this end, the developed procedure determines the optimal operating voltage as a function of the cable length in order to reduce the reactive power demand and maximize the transmitted power. The proposed approach has been compared with other methods in the literature based on lumped parameter models, as well as with the Ossanna method for transmission line modeling. The accuracy of the developed procedure proves to be satisfactory, particularly in relation to its ease of application| File | Dimensione | Formato | |
|---|---|---|---|
|
Ravazzolo_MarcoTullio.pdf
Accesso riservato
Dimensione
6.11 MB
Formato
Adobe PDF
|
6.11 MB | Adobe PDF |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/94176