Peripheral nerve injuries represent a significant clinical challenge, as they can lead to partial or complete loss of motor and sensory functions, severely affecting patients' quality of life. Currently, autogenous nerve grafting is considered the gold standard for the repair of large peripheral nerve gaps. However, this approach presents several limitations, including the shortage of donor tissue and the risk of complications at the donor site. To overcome these drawbacks, recent research has focused on the development of nerve guidance conduits (NGCs), engineered devices designed to promote peripheral nerve regeneration by providing a supportive environment for axonal growth. Through a review of the scientific literature, this study analyzes the main biomaterials used in the fabrication of nerve guidance conduits, with particular emphasis on their mechanical properties. The analysis highlights that the mechanical behavior of these biomaterials is a key factor in NGCs design, as it directly influences the structural stability of the conduit, its ability to follow physiological nerve movements, and its effectiveness in supporting the nerve regeneration process.

Le lesioni del nervo periferico rappresentano una problematica clinica ad oggi rilevante, in quanto possono determinare una perdita parziale o totale delle funzioni motorie e sensoriali, con un impatto non indifferente sulla qualità della vita del paziente. Attualmente, il trapianto autologo costituisce il trattamento più utilizzato per la riparazione di lesioni nervose di grandi dimensioni; tuttavia, tale approccio presenta importanti limitazioni, tra cui la scarsa disponibilità di tessuto donatore e le complicanze che possono sorgere nel sito di prelievo. Per superare queste criticità, negli ultimi anni la ricerca scientifica si è concentrata sullo sviluppo di neuroguide, dispositivi progettati per facilitare la rigenerazione nervosa e per creare un ambiente favorevole alla ricrescita del nervo lesionato. Attraverso una revisione della letteratura scientifica, questa ricerca analizza i principali biomateriali impiegati nella realizzazione delle neuroguide, con particolare attenzione alle loro proprietà meccaniche. L'analisi evidenzia come la natura meccanica costituisca un fattore determinante nella progettazione delle neuroguide, influenzandone la stabilità strutturale, la capacità di adattarsi ai movimenti del nervo e l'efficacia nel supportare il processo di rigenerazione.

Analisi delle proprietà meccaniche di neuroguide per la rigenerazione nervosa

BERLATO, MICHELA
2025/2026

Abstract

Peripheral nerve injuries represent a significant clinical challenge, as they can lead to partial or complete loss of motor and sensory functions, severely affecting patients' quality of life. Currently, autogenous nerve grafting is considered the gold standard for the repair of large peripheral nerve gaps. However, this approach presents several limitations, including the shortage of donor tissue and the risk of complications at the donor site. To overcome these drawbacks, recent research has focused on the development of nerve guidance conduits (NGCs), engineered devices designed to promote peripheral nerve regeneration by providing a supportive environment for axonal growth. Through a review of the scientific literature, this study analyzes the main biomaterials used in the fabrication of nerve guidance conduits, with particular emphasis on their mechanical properties. The analysis highlights that the mechanical behavior of these biomaterials is a key factor in NGCs design, as it directly influences the structural stability of the conduit, its ability to follow physiological nerve movements, and its effectiveness in supporting the nerve regeneration process.
2025
Analysis of the Mechanical Properties of Nerve Conduits for Nerve Repair
Le lesioni del nervo periferico rappresentano una problematica clinica ad oggi rilevante, in quanto possono determinare una perdita parziale o totale delle funzioni motorie e sensoriali, con un impatto non indifferente sulla qualità della vita del paziente. Attualmente, il trapianto autologo costituisce il trattamento più utilizzato per la riparazione di lesioni nervose di grandi dimensioni; tuttavia, tale approccio presenta importanti limitazioni, tra cui la scarsa disponibilità di tessuto donatore e le complicanze che possono sorgere nel sito di prelievo. Per superare queste criticità, negli ultimi anni la ricerca scientifica si è concentrata sullo sviluppo di neuroguide, dispositivi progettati per facilitare la rigenerazione nervosa e per creare un ambiente favorevole alla ricrescita del nervo lesionato. Attraverso una revisione della letteratura scientifica, questa ricerca analizza i principali biomateriali impiegati nella realizzazione delle neuroguide, con particolare attenzione alle loro proprietà meccaniche. L'analisi evidenzia come la natura meccanica costituisca un fattore determinante nella progettazione delle neuroguide, influenzandone la stabilità strutturale, la capacità di adattarsi ai movimenti del nervo e l'efficacia nel supportare il processo di rigenerazione.
Neuroguide
Rigenerazione
Nervi
Biomateriali
Ingegneria tissutale
File in questo prodotto:
File Dimensione Formato  
Berlato_Michela.pdf

accesso aperto

Dimensione 2.58 MB
Formato Adobe PDF
2.58 MB Adobe PDF Visualizza/Apri

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/114468