Magnetic resonance imaging represents a high-value method in the evaluation of pelvic endometriosis, particularly in the characterization of deep forms and in preoperative mapping. Conventional sequences, however, provide predominantly morphological and qualitative information, allowing only an indirect assessment of the fibrotic component, which is particularly relevant in deep endometriosis lesions. The present work explores Magnetization Transfer (MT) as a tissue characterization technique sensitive to the macromolecular component. After recalling the physical basis of magnetic resonance imaging and the two-pool model, which distinguishes free water protons from those bound to macromolecules, the work describes the mechanism of selective off-resonance saturation and the Magnetization Transfer Ratio (MTR), a semi-quantitative parameter derivable from the comparison between acquisitions obtained without and with an MT saturation pulse, without the need for a contrast agent. The histopathological rationale for applying the technique to endometriosis is then illustrated: the marked fibromuscular component and increased collagen deposition of deep lesions suggest a different MT behavior compared to reference tissues. The aim of the study is to evaluate the feasibility and potential added value of MT in the MRI examination of patients with endometriosis, with a particular focus on the fibrotic component. In this prospective, single-center, observational study, 14 patients undergoing pelvic MRI at 1.5T for suspected endometriosis were included; a pair of T1-weighted gradient echo sequences acquired without and with an MT saturation pulse was added to the conventional protocol. The MT images were independently evaluated by two radiologists using a 5-point Likert scale (lesion visibility, margin delineation, diagnostic confidence, identification of the fibrotic component, and overall assessment of MT utility). As a secondary exploratory objective, the MTR measured via ROI in 11 lesions across 8 patients was compared with the activity classification of the lesions, as well as with ADC, T2 signal, and post-contrast T1 behavior. The expert investigator assigned the highest mean score to the identification of the fibrotic component (4.25 ± 0.89) and a mean score of 4.00 ± 0.53 to diagnostic confidence; the overall assessment was ≥ 4 in 13 out of 14 patients (92.9%). Inter-observer agreement between the two radiologists was high for the overall assessment (ICC = 0.893) and for diagnostic confidence (ICC = 0.821), and good for the identification of fibrosis (ICC = 0.712). MTR showed no significant differences between active and non-active lesions (p=0.442) nor a correlation with ADC, whereas ADC was significantly higher in active lesions (p=0.006) and T2 hyperintensity was associated with activity (p=0.024). The results, preliminary and exploratory given the small sample size, suggest that MT may represent a complement to conventional MRI sequences, with a predominantly qualitative contribution to tissue characterization and to the evaluation of the fibrotic component, rather than acting as a standalone quantitative biomarker.

La risonanza magnetica rappresenta una metodica di elevato valore nella valutazione dell’endometriosi pelvica, in particolare nella caratterizzazione delle forme profonde e nel mapping preoperatorio. Le sequenze convenzionali forniscono tuttavia informazioni prevalentemente morfologiche e qualitative, consentendo di valutare solo indirettamente la componente fibrotica, particolarmente rilevante nelle lesioni di endometriosi profonda. Il presente lavoro esplora il trasferimento di magnetizzazione (Magnetization Transfer, MT) quale tecnica di caratterizzazione tissutale sensibile alla componente macromolecolare. Dopo aver richiamato le basi fisiche della risonanza magnetica e il modello a due pool, che distingue i protoni dell’acqua libera da quelli vincolati alle macromolecole, il lavoro descrive il meccanismo della saturazione selettiva off-resonance e il Magnetization Transfer Ratio (MTR), parametro semiquantitativo ricavabile dal confronto tra acquisizioni ottenute senza e con impulso di saturazione MT, senza necessità di mezzo di contrasto. Viene quindi illustrato il razionale istopatologico dell’applicazione della tecnica all’endometriosi: la marcata componente fibromuscolare e l’aumentato deposito di collagene delle lesioni profonde suggeriscono un comportamento MT differente rispetto ai tessuti di riferimento. Scopo dello studio è valutare la fattibilità e il potenziale valore aggiunto della MT nell’esame RM delle pazienti con endometriosi, con particolare attenzione alla componente fibrotica. Nello studio, prospettico, monocentrico e osservazionale, sono state incluse 14 pazienti sottoposte a RM pelvica a 1,5T per sospetta endometriosi; al protocollo convenzionale è stata aggiunta una coppia di sequenze gradient echo pesate in T1 acquisite senza e con impulso di saturazione MT. Le immagini MT sono state valutate in modo indipendente da due medici radiologi mediante una scala Likert a 5 punti (visibilità della lesione, delimitazione dei margini, confidenza diagnostica, identificazione della componente fibrotica e valutazione finale dell’utilità della MT). Come obiettivo esplorativo secondario, la MTR misurata mediante ROI in 11 lesioni di 8 pazienti è stata confrontata con la classificazione di attività delle lesioni e con ADC, segnale T2 e comportamento T1 post-contrasto. Lo sperimentatore esperto ha attribuito il punteggio medio più elevato all’identificazione della componente fibrotica (4,25 ± 0,89) e un punteggio medio di 4,00 ± 0,53 alla confidenza diagnostica; la valutazione finale è risultata ≥ 4 in 13 pazienti su 14 (92,9%). La concordanza tra i due radiologi è risultata elevata per la valutazione finale (ICC = 0,893) e per la confidenza diagnostica (ICC = 0,821) e buona per l’identificazione della fibrosi (ICC = 0,712). La MTR non ha mostrato differenze significative tra lesioni attive e non attive (p = 0,442) né correlazione con l’ADC, mentre l’ADC è risultato significativamente più elevato nelle lesioni attive (p = 0,006) e l’iperintensità T2 è risultata associata all’attività (p = 0,024). I risultati, preliminari ed esplorativi data la ridotta numerosità del campione, suggeriscono che la MT possa rappresentare un complemento alle sequenze RM convenzionali, con un contributo soprattutto qualitativo alla caratterizzazione tissutale e alla valutazione della componente fibrotica, piuttosto che come biomarcatore quantitativo autonomo.

Magnetization Transfer per la caratterizzazione della fibrosi dell'endometriosi mediante Risonanza Magnetica.

TIOZZO MEO AMBROSI, FEDERICO
2025/2026

Abstract

Magnetic resonance imaging represents a high-value method in the evaluation of pelvic endometriosis, particularly in the characterization of deep forms and in preoperative mapping. Conventional sequences, however, provide predominantly morphological and qualitative information, allowing only an indirect assessment of the fibrotic component, which is particularly relevant in deep endometriosis lesions. The present work explores Magnetization Transfer (MT) as a tissue characterization technique sensitive to the macromolecular component. After recalling the physical basis of magnetic resonance imaging and the two-pool model, which distinguishes free water protons from those bound to macromolecules, the work describes the mechanism of selective off-resonance saturation and the Magnetization Transfer Ratio (MTR), a semi-quantitative parameter derivable from the comparison between acquisitions obtained without and with an MT saturation pulse, without the need for a contrast agent. The histopathological rationale for applying the technique to endometriosis is then illustrated: the marked fibromuscular component and increased collagen deposition of deep lesions suggest a different MT behavior compared to reference tissues. The aim of the study is to evaluate the feasibility and potential added value of MT in the MRI examination of patients with endometriosis, with a particular focus on the fibrotic component. In this prospective, single-center, observational study, 14 patients undergoing pelvic MRI at 1.5T for suspected endometriosis were included; a pair of T1-weighted gradient echo sequences acquired without and with an MT saturation pulse was added to the conventional protocol. The MT images were independently evaluated by two radiologists using a 5-point Likert scale (lesion visibility, margin delineation, diagnostic confidence, identification of the fibrotic component, and overall assessment of MT utility). As a secondary exploratory objective, the MTR measured via ROI in 11 lesions across 8 patients was compared with the activity classification of the lesions, as well as with ADC, T2 signal, and post-contrast T1 behavior. The expert investigator assigned the highest mean score to the identification of the fibrotic component (4.25 ± 0.89) and a mean score of 4.00 ± 0.53 to diagnostic confidence; the overall assessment was ≥ 4 in 13 out of 14 patients (92.9%). Inter-observer agreement between the two radiologists was high for the overall assessment (ICC = 0.893) and for diagnostic confidence (ICC = 0.821), and good for the identification of fibrosis (ICC = 0.712). MTR showed no significant differences between active and non-active lesions (p=0.442) nor a correlation with ADC, whereas ADC was significantly higher in active lesions (p=0.006) and T2 hyperintensity was associated with activity (p=0.024). The results, preliminary and exploratory given the small sample size, suggest that MT may represent a complement to conventional MRI sequences, with a predominantly qualitative contribution to tissue characterization and to the evaluation of the fibrotic component, rather than acting as a standalone quantitative biomarker.
2025
Magnetization Transfer for the Characterization of Endometriosis Fibrosis Using Magnetic Resonance Imaging.
La risonanza magnetica rappresenta una metodica di elevato valore nella valutazione dell’endometriosi pelvica, in particolare nella caratterizzazione delle forme profonde e nel mapping preoperatorio. Le sequenze convenzionali forniscono tuttavia informazioni prevalentemente morfologiche e qualitative, consentendo di valutare solo indirettamente la componente fibrotica, particolarmente rilevante nelle lesioni di endometriosi profonda. Il presente lavoro esplora il trasferimento di magnetizzazione (Magnetization Transfer, MT) quale tecnica di caratterizzazione tissutale sensibile alla componente macromolecolare. Dopo aver richiamato le basi fisiche della risonanza magnetica e il modello a due pool, che distingue i protoni dell’acqua libera da quelli vincolati alle macromolecole, il lavoro descrive il meccanismo della saturazione selettiva off-resonance e il Magnetization Transfer Ratio (MTR), parametro semiquantitativo ricavabile dal confronto tra acquisizioni ottenute senza e con impulso di saturazione MT, senza necessità di mezzo di contrasto. Viene quindi illustrato il razionale istopatologico dell’applicazione della tecnica all’endometriosi: la marcata componente fibromuscolare e l’aumentato deposito di collagene delle lesioni profonde suggeriscono un comportamento MT differente rispetto ai tessuti di riferimento. Scopo dello studio è valutare la fattibilità e il potenziale valore aggiunto della MT nell’esame RM delle pazienti con endometriosi, con particolare attenzione alla componente fibrotica. Nello studio, prospettico, monocentrico e osservazionale, sono state incluse 14 pazienti sottoposte a RM pelvica a 1,5T per sospetta endometriosi; al protocollo convenzionale è stata aggiunta una coppia di sequenze gradient echo pesate in T1 acquisite senza e con impulso di saturazione MT. Le immagini MT sono state valutate in modo indipendente da due medici radiologi mediante una scala Likert a 5 punti (visibilità della lesione, delimitazione dei margini, confidenza diagnostica, identificazione della componente fibrotica e valutazione finale dell’utilità della MT). Come obiettivo esplorativo secondario, la MTR misurata mediante ROI in 11 lesioni di 8 pazienti è stata confrontata con la classificazione di attività delle lesioni e con ADC, segnale T2 e comportamento T1 post-contrasto. Lo sperimentatore esperto ha attribuito il punteggio medio più elevato all’identificazione della componente fibrotica (4,25 ± 0,89) e un punteggio medio di 4,00 ± 0,53 alla confidenza diagnostica; la valutazione finale è risultata ≥ 4 in 13 pazienti su 14 (92,9%). La concordanza tra i due radiologi è risultata elevata per la valutazione finale (ICC = 0,893) e per la confidenza diagnostica (ICC = 0,821) e buona per l’identificazione della fibrosi (ICC = 0,712). La MTR non ha mostrato differenze significative tra lesioni attive e non attive (p = 0,442) né correlazione con l’ADC, mentre l’ADC è risultato significativamente più elevato nelle lesioni attive (p = 0,006) e l’iperintensità T2 è risultata associata all’attività (p = 0,024). I risultati, preliminari ed esplorativi data la ridotta numerosità del campione, suggeriscono che la MT possa rappresentare un complemento alle sequenze RM convenzionali, con un contributo soprattutto qualitativo alla caratterizzazione tissutale e alla valutazione della componente fibrotica, piuttosto che come biomarcatore quantitativo autonomo.
Risonanza Magnetica
Endometriosi
Magn. Transfer
File in questo prodotto:
File Dimensione Formato  
Tesi_MT_ENDOMETRIOSI.pdf

Accesso riservato

Dimensione 8.22 MB
Formato Adobe PDF
8.22 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/119919