Background Modern-day T2 and T2* mapping techniques allow for precise and quantitative characterization of the myocardial tissue and can be used as a diagnostic tool in various heart conditions such as myocardial infarction, myocarditis, Anderson-Fabry disease and myocardial iron overload without the necessity of invasive exams; to correctly identify these diseases, however, normal values should be established in order to confront them with the data obtained with the mapping techniques. These sets of data differ from center to center based on the sequences used to obtain the images, and on the scanner used to perform the exam: thus, each center should obtain their own set of normal values for T2 and T2* mapping, which can be applied to the sequences used and on the on-site scanner. Objectives The objective of this study was to obtain segmental and global T2 and T2* values of the myocardium in healthy subjects as a normal-value range using T2p-SSFP and MEGE sequences with a Siemens scanner and to establish correlations between these values and the physiological characteristics of the enrolled subjects. Methods 50 healthy subjects aged 20 to 70 years old (male to female ratio 1:1) underwent CMR. Basal, mid-ventricular and apical short axis slices were obtained with T2p-SSFP sequences for T2 evaluation and with Black Blood Multi-Echo Gradient-Echo (MEGE) sequences for T2* evaluation. Image analysis was performed with commercially available post-processing software. T2 and T2* values were evaluated in all 16 left ventricular AHA segment, and the global T2 and T2* values were the average of the single segments’ values. Results NOT AVAILABLE Conclusions NOT AVAILABLE

Background Le odierne tecniche di mapping T2 e T2* permettono una precisa caratterizzazione quantitativa del tessuto miocardico e possono essere utilizzate per diagnosticare numerose condizioni patologiche quali l’ischemia miocardica, la miocardite, la malattia di Anderson-Fabry e la siderosi cardiaca senza l’ausilio di metodiche invasive; per poter identificare correttamente queste condizioni, occorre tuttavia avere a disposizione valori di normalità con cui confrontare i dati ottenuti al mapping. Questi dati differiscono in base alle sequenze utilizzate durante l’acquisizione e all’apparecchiatura utilizzata: ciò rende necessario che i singoli centri provvedano a procurarsi dei valori di riferimento specifici e validi per i mezzi a loro disposizione. Obiettivi L’obiettivo dello studio è di ottenere valori segmentali e globali di T2 e T2* del miocardio di soggetti sani come range di normalità utilizzando sequenze T2p-SSFP e MEGE con uno scanner Siemens e stabilire l’associazione tra tali valori e le variabili fisiologiche dei soggetti reclutati. Metodi 50 soggetti sani di età compresa tra i 20 e i 70 anni (M:F=1:1) sono stati sottoposti ad una risonanza magnetica cardiaca. Sezioni basali, medie e apicali del ventricolo sinistro sono state ottenute mediante sequenze T2p-SSFP per il T2 e mediante sequenze black blood Multi-Echo Gradient Echo (MEGE) per il T2*. L’analisi delle immagini è stata svolta con software di post-processing disponibili sul mercato. I valori di T2 e T2* sono stati valutati in tutti i 16 segmenti miocardici AHA e il valore globale corrisponde alla media dei singoli segmenti. Risultati NON DISPONIBILI Conclusioni NON DISPONIBILI

T2 e T2* mapping miocardico con approccio segmentario quantitativo: valori di normalità, effetti dell’invecchiamento e differenze di genere

GAMBATO, SEBASTIANO
2021/2022

Abstract

Background Modern-day T2 and T2* mapping techniques allow for precise and quantitative characterization of the myocardial tissue and can be used as a diagnostic tool in various heart conditions such as myocardial infarction, myocarditis, Anderson-Fabry disease and myocardial iron overload without the necessity of invasive exams; to correctly identify these diseases, however, normal values should be established in order to confront them with the data obtained with the mapping techniques. These sets of data differ from center to center based on the sequences used to obtain the images, and on the scanner used to perform the exam: thus, each center should obtain their own set of normal values for T2 and T2* mapping, which can be applied to the sequences used and on the on-site scanner. Objectives The objective of this study was to obtain segmental and global T2 and T2* values of the myocardium in healthy subjects as a normal-value range using T2p-SSFP and MEGE sequences with a Siemens scanner and to establish correlations between these values and the physiological characteristics of the enrolled subjects. Methods 50 healthy subjects aged 20 to 70 years old (male to female ratio 1:1) underwent CMR. Basal, mid-ventricular and apical short axis slices were obtained with T2p-SSFP sequences for T2 evaluation and with Black Blood Multi-Echo Gradient-Echo (MEGE) sequences for T2* evaluation. Image analysis was performed with commercially available post-processing software. T2 and T2* values were evaluated in all 16 left ventricular AHA segment, and the global T2 and T2* values were the average of the single segments’ values. Results NOT AVAILABLE Conclusions NOT AVAILABLE
2021
T2 and T2* myocardial mapping with segmental quantitative approach: normal values, effects of ageing and gender differences
Background Le odierne tecniche di mapping T2 e T2* permettono una precisa caratterizzazione quantitativa del tessuto miocardico e possono essere utilizzate per diagnosticare numerose condizioni patologiche quali l’ischemia miocardica, la miocardite, la malattia di Anderson-Fabry e la siderosi cardiaca senza l’ausilio di metodiche invasive; per poter identificare correttamente queste condizioni, occorre tuttavia avere a disposizione valori di normalità con cui confrontare i dati ottenuti al mapping. Questi dati differiscono in base alle sequenze utilizzate durante l’acquisizione e all’apparecchiatura utilizzata: ciò rende necessario che i singoli centri provvedano a procurarsi dei valori di riferimento specifici e validi per i mezzi a loro disposizione. Obiettivi L’obiettivo dello studio è di ottenere valori segmentali e globali di T2 e T2* del miocardio di soggetti sani come range di normalità utilizzando sequenze T2p-SSFP e MEGE con uno scanner Siemens e stabilire l’associazione tra tali valori e le variabili fisiologiche dei soggetti reclutati. Metodi 50 soggetti sani di età compresa tra i 20 e i 70 anni (M:F=1:1) sono stati sottoposti ad una risonanza magnetica cardiaca. Sezioni basali, medie e apicali del ventricolo sinistro sono state ottenute mediante sequenze T2p-SSFP per il T2 e mediante sequenze black blood Multi-Echo Gradient Echo (MEGE) per il T2*. L’analisi delle immagini è stata svolta con software di post-processing disponibili sul mercato. I valori di T2 e T2* sono stati valutati in tutti i 16 segmenti miocardici AHA e il valore globale corrisponde alla media dei singoli segmenti. Risultati NON DISPONIBILI Conclusioni NON DISPONIBILI
Risonanza Cardiaca
Salute
Miocardio