The implementation of the law 101 released on 31 July 2020 establishes the standard for the safety, security, and radiation protection, relative also to the nuclear medicine department. Specifically, the law adopts some strategies able to optimize the radiation exposure in case of medical procedures in order to keep individual doses as low as reasonably achievable. The aim of the present study was to compare data about radiation exposure in patients undergoing myocardial scintigraphy, with a double-day protocol, before and after the introduction of the new regulamentation. Indeed, data concerning 60 patients who underwent myocardial scintigraphy (30 before and 30 patients after the implementation of the 110/2020 law) will be compared in order to assess if the level of radiation exposure has changed, also considering the hybrid system. The evaluation of the dosage associated with the amount of prepared/administered radioactivity and the introduction of a new regulamentation represent a challenge that should be faced and managed by the radiology technician.

Il recepimento del Decreto Legislativo 31 luglio 2020, 101 che stabilisce norme fondamentali di sicurezza relative alla protezione contro i pericoli derivanti dall’esposizione delle radiazioni ionizzanti, ha portato i reparti interessati, tra cui quello di medicina nucleare, ad adattare le proprie pratiche con quanto indicato all’interno del Decreto. In particolare, ad adottare strategie necessarie al fine di ottimizzare la radioprotezione degli individui soggetti ad esposizioni mediche allo scopo di mantenere al minimo ragionevolmente ottenibile le dosi individuali. Lo scopo del presente studio è stato di valutare all’interno del reparto di medicina nucleare e, in particolare, nell’indagine di scintigrafia miocardica con protocollo a doppia giornata, se siano state attuate le direttive e quanto queste abbiano influito sulla dose di radiofarmaco somministrata al paziente e, di conseguenza, sull’entità dell’esposizione individuale, considerando anche l’utilizzo delle macchine ibride. Attraverso una raccolta dati riguardante in totale 60 pazienti che hanno effettuato una scintigrafia miocardica, 30 prima dell’attuazione del D.Lgs. 101/2020 e 30 dopo l’attuazione del D.Lgs,101/2020 è stato possibile effettuare un confronto sul livello di dose somministrato al singolo paziente. La valutazione della dose, legata sia al radiofarmaco preparato/somministrato che all’esecuzione dell’esame ibrido e l' introduzione di un nuovo decreto in ambito radioprotezionistico rappresentano sfide che un tecnico di radiologia medica deve imparare ad affrontare e gestire.

La scintigrafia miocardica: analisi della dose erogata al paziente in conformità con il nuovo D.Lgs 101/2020

REA, MATILDE
2021/2022

Abstract

The implementation of the law 101 released on 31 July 2020 establishes the standard for the safety, security, and radiation protection, relative also to the nuclear medicine department. Specifically, the law adopts some strategies able to optimize the radiation exposure in case of medical procedures in order to keep individual doses as low as reasonably achievable. The aim of the present study was to compare data about radiation exposure in patients undergoing myocardial scintigraphy, with a double-day protocol, before and after the introduction of the new regulamentation. Indeed, data concerning 60 patients who underwent myocardial scintigraphy (30 before and 30 patients after the implementation of the 110/2020 law) will be compared in order to assess if the level of radiation exposure has changed, also considering the hybrid system. The evaluation of the dosage associated with the amount of prepared/administered radioactivity and the introduction of a new regulamentation represent a challenge that should be faced and managed by the radiology technician.
2021
Myocardial scintigraphy: the analysis of radiation dosage based on the new regulamentation 101/2020
Il recepimento del Decreto Legislativo 31 luglio 2020, 101 che stabilisce norme fondamentali di sicurezza relative alla protezione contro i pericoli derivanti dall’esposizione delle radiazioni ionizzanti, ha portato i reparti interessati, tra cui quello di medicina nucleare, ad adattare le proprie pratiche con quanto indicato all’interno del Decreto. In particolare, ad adottare strategie necessarie al fine di ottimizzare la radioprotezione degli individui soggetti ad esposizioni mediche allo scopo di mantenere al minimo ragionevolmente ottenibile le dosi individuali. Lo scopo del presente studio è stato di valutare all’interno del reparto di medicina nucleare e, in particolare, nell’indagine di scintigrafia miocardica con protocollo a doppia giornata, se siano state attuate le direttive e quanto queste abbiano influito sulla dose di radiofarmaco somministrata al paziente e, di conseguenza, sull’entità dell’esposizione individuale, considerando anche l’utilizzo delle macchine ibride. Attraverso una raccolta dati riguardante in totale 60 pazienti che hanno effettuato una scintigrafia miocardica, 30 prima dell’attuazione del D.Lgs. 101/2020 e 30 dopo l’attuazione del D.Lgs,101/2020 è stato possibile effettuare un confronto sul livello di dose somministrato al singolo paziente. La valutazione della dose, legata sia al radiofarmaco preparato/somministrato che all’esecuzione dell’esame ibrido e l' introduzione di un nuovo decreto in ambito radioprotezionistico rappresentano sfide che un tecnico di radiologia medica deve imparare ad affrontare e gestire.
Scintigrafia
Gamma camera
LDR
radiofarmaco
File in questo prodotto:
File Dimensione Formato  
Rea_Matilde.pdf.pdf

accesso riservato

Dimensione 2.14 MB
Formato Adobe PDF
2.14 MB Adobe PDF

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/38070