Introduction: The problem linked to the presence of PFAS in the aqueduct water involves several affected red areas, with a spill point identified at a company in Trissino (Miteni). A solution is needed to ensure the safety of the population by changing the source of supply of the aqueduct. Chemical description of PFAS: PFAS are compounds with a specific chemical formula and are present in various commonly used materials. There are effective treatments to eliminate them from water, but it is important to respect the established legal limits. PFAS have the potential to cause adverse health effects. (Personal blood test reports as they have varied over the years). Supply network: The journey of water from Camazzole to Montagnana through the adduction network which has undergone significant changes. Reservoir: Architectural drawings and hydraulic technical aspects of the tank: volume, overflow level, average and max flow rate, pumping system, water level trend.
Introduzione: Il problema legato alla presenza di PFAS nell'acqua dell'acquedotto coinvolge diverse zone rosse interessate, con un punto di sversamento identificato presso un'azienda a Trissino (Miteni). È necessaria una soluzione per garantire la sicurezza della popolazione mediante il cambiamento della fonte di approvvigionamento dell'acquedotto. Descrizione chimica dei PFAS: I PFAS sono composti con una specifica formula chimica e sono presenti in vari materiali di uso comune. Esistono trattamenti efficaci per eliminarli dall'acqua, ma è importante rispettare i limiti di legge stabiliti. I PFAS possono potenzialmente causare effetti nocivi sulla salute. (Referti analisi del sangue personali come sono variati negli anni). Rete di adduzione: Il viaggio dell'acqua da Camazzole a Montagnana attraverso la rete di adduzione che ha subito variazioni significative. Serbatoio: Disegni architettonici e aspetti tecnici idraulici del serbatoio: volume, quota di sfioro, portata media e max, impianto di pompaggio, andamento livelli idrici.
Emergenza PFAS: progettazione e costruzione di un serbatoio a Montagnana
ZONATO, MARTINA
2023/2024
Abstract
Introduction: The problem linked to the presence of PFAS in the aqueduct water involves several affected red areas, with a spill point identified at a company in Trissino (Miteni). A solution is needed to ensure the safety of the population by changing the source of supply of the aqueduct. Chemical description of PFAS: PFAS are compounds with a specific chemical formula and are present in various commonly used materials. There are effective treatments to eliminate them from water, but it is important to respect the established legal limits. PFAS have the potential to cause adverse health effects. (Personal blood test reports as they have varied over the years). Supply network: The journey of water from Camazzole to Montagnana through the adduction network which has undergone significant changes. Reservoir: Architectural drawings and hydraulic technical aspects of the tank: volume, overflow level, average and max flow rate, pumping system, water level trend.File | Dimensione | Formato | |
---|---|---|---|
Tesi_EMERGENZAPFAS.pdf
accesso aperto
Dimensione
2.64 MB
Formato
Adobe PDF
|
2.64 MB | Adobe PDF | Visualizza/Apri |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License