External Post-Tension is a reinforcement method currently being tested and applied to arched structures. The effectiveness of this method, as demonstrated in the first experiments, makes it a promising system for improving the load capacity of arches. To further study External Post-Tension, a parametric analysis was performed on the application of the system to a masonry drop arch structure. The trend of the load multiplier of the structure was examined by varying the tension parameters of the cable, number of wires placed, number of connectors applied, and eccentricity of connectors. To develop this analysis, an evaluation of the resistive capacity of the connectors, a key element of the system structure, was conducted, as well as program functions useful for uniformly distributing the connectors in the intrados of the arch and assigning a specific eccentricity to each.
La Post-Tensione Esterna è un metodo di rinforzo, attualmente in fase di sperimentazione, applicabile alle strutture ad arco. L'efficacia di tale metodo, dimostrata sin dalle prime sperimentazioni, lo rende un promettente sistema di miglioramento della capacità di carico degli archi. Per approfondire lo studio della Post-Tensione Esterna, è stata eseguita un'analisi parametrica relativa all'applicazione del sistema su una struttura ad arco ribassato in muratura. Al variare dei parametri di tensione sulla fune, numero di funi collocate, numero di connettori applicati e dell'eccentricità dei connettori, è stato esaminato l'andamento del moltiplicatore di carico della struttura, allo scopo di determinare il modo in cui tali parametri incidono su di esso. Per sviluppare questa analisi è stata condotta una valutazione della capacità resistiva dei connettori, elemento chiave della struttura del sistema e, inoltre, sono state elaborate delle funzioni di programma utili a distribuire uniformemente i connettori nell'intradosso dell'arco e ad assegnare a ciascuno una specifica eccentricità.
Valutazione parametrica dell'efficacia della Post-Tensione esterna come metodo di rinforzo di strutture ad arco ribassato in muratura
PEGORARO, DANIEL
2023/2024
Abstract
External Post-Tension is a reinforcement method currently being tested and applied to arched structures. The effectiveness of this method, as demonstrated in the first experiments, makes it a promising system for improving the load capacity of arches. To further study External Post-Tension, a parametric analysis was performed on the application of the system to a masonry drop arch structure. The trend of the load multiplier of the structure was examined by varying the tension parameters of the cable, number of wires placed, number of connectors applied, and eccentricity of connectors. To develop this analysis, an evaluation of the resistive capacity of the connectors, a key element of the system structure, was conducted, as well as program functions useful for uniformly distributing the connectors in the intrados of the arch and assigning a specific eccentricity to each.File | Dimensione | Formato | |
---|---|---|---|
Pegoraro_Daniel.pdf
accesso riservato
Dimensione
2.88 MB
Formato
Adobe PDF
|
2.88 MB | Adobe PDF |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/72057