Introduction: The pituitary gland is an intracranial endocrine gland located in the pituitary fossa of the basisphenoid bone and divided into two portions, the adenohypophysis and the neurohypophysis. Most pituitary disorders, at least until they also affect other surrounding structures, can cause silent clinical symptoms. In veterinary neurology, Magnetic Resonance Imaging (MRI) plays a key role in the early diagnosis of these specific afflictions but, compared to other species, the MRI study of the pituitary gland is complicated by the considerable intraspecific anatomical variation and the small size of the gland. Despite this, the few studies on the subject identify the pituitary MRI signal in T1-weighted images as hyperintense. The true nature of this hyperintensity has not yet been fully identified; some studies attribute it to neurosecretory granules of vasopressin, others to lipid droplets of glial cells of the neurohypophysis, still others to the presence of adipose tissue and adipocytes in the basisphenoid bone region. Objective of the study: To analyze the MRI signal of the cat pituitary gland to characterize pituitary intensity in T1-weighted images. To also evaluate how scanning modalities affect the accuracy of MRI images in order to provide useful insights into the best modalities for scanning the feline pituitary gland in Veterinary Medicine. Materials and Methods: Retrospective study of 61 MRIs of European mesocephalic cats and prospective study of 11 MRIs of European mesocephalic cats. Transverse T1-weighted, sagittal T2-weighted, and transverse T2-weighted sequences with no evidence of intracranial pathology were analyzed. Results: Of the 61 retrospective cases, 33/61 (54%) hypophyses were contained within a single slice; of these, 14/33 (42%) were slightly hyperintense while 19/33 (58%) were markedly hyperintense in T1-weighted images. The remaining 28/61 (46%) pituitary glands were bisected by the slice; in the rostral slice, 14/28 (50%) pituitary glands were isointense to the encephalic white matter, 11/28 (39%) were slightly hyperintense and 3/28 (11%) were markedly hyperintense. In the caudal portion, however, 8/28 (29%) pituitary glands were moderately intense while 20/28 (71%) were markedly hyperintense in T1-weighted sequences. In the prospective analysis, in which all slice passed entirely through the pituitary, 4/9 (44%) were mildly hyperintense while 5/9 (56%) were markedly hyperintense in T1-weighted images. Depending on the slice location (OrC, PAb and RRS), in most cases the pituitary was homogeneous if the slice was OrC, with a BS and BS V - Pd if it was PAb and inhomogeneous, hyperintense ring, with a BS V - NoPd if it was RRS. Conclusions: The cat pituitary gland appears hyperintense in T1-weighted MR sequences. The position of the slice is critical to clearly visualize the pituitary gland and to avoid partial volume mediation with retrosellar structures that could alter the MR signal of the gland.

Introduzione: L’ipofisi è una ghiandola endocrina intracranica situata nella fossa ipofisaria dell’osso basisfenoide e suddivisa in due porzioni, l’adenoipofisi e la neuroipofisi. La maggior parte delle patologie ipofisarie, perlomeno fino a quando non interessano anche altre strutture circostanti, possono causare una sintomatologia clinica silente. In neurologia veterinaria la Risonanza Magnetica (RM) riveste un ruolo fondamentale nella diagnosi precoce di queste specifiche affezioni ma, rispetto alle altre specie, lo studio RM dell’ipofisi è complicato dalla notevole variazione anatomica intraspecifica e dalle ridotte dimensioni della ghiandola. Nonostante ciò, i pochi studi al riguardo identificano come iperintenso il segnale RM ipofisario nelle immagini pesate in T1. La reale natura di questa iperintensità non è ancora stata del tutto identificata; alcuni studi la attribuiscono ai granuli neurosecretori di vasopressina, altri ai droplets lipidici delle cellule gliali della neuroipofisi, altri ancora alla presenza di tessuto adiposo e adipociti nella regione dell’osso basisfenoide. Obiettivo dello studio: Analizzare il segnale RM dell’ipofisi del gatto per caratterizzare l’intensità ipofisaria nelle immagini pesate in T1. Valutare, inoltre, come le modalità di scansione influiscano sull’accuratezza delle immagini RM al fine di fornire indicazioni utili sulle migliori modalità di scansione dell’ipofisi felina in Medicina Veterinaria. Materiali e metodi: Studio retrospettivo di 61 RM di gatti europei mesocefalici e studio prospettico di 11 RM di gatti europei mesocefalici. Sono state analizzate le sequenze pesate in T1 trasverse, T2 sagittali e T2 trasverse senza evidenze di patologie intracraniche. Risultati: Dei 61 casi retrospettivi, 33/61 (54%) ipofisi erano contenute all’interno di un singolo slice; di queste, 14/33 (42%) erano leggermente iperintense mentre 19/33 (58%) erano nettamente iperintense nelle immagini pesate in T1. Le restanti 28/61 (46%) ipofisi erano divise in due dallo slice; nella fetta orale, 14/28 (50%) ipofisi erano isointense alla sostanza bianca encefalica, 11/28 (39%) erano leggermente iperintense e 3/28 (11%) erano nettamente iperintense. Nella porzione aborale, invece, 8/28 (29%) ipofisi erano mediamente intense mentre 20/28 (71%) erano nettamente iperintense nelle sequenze pesate in T1. Nell’analisi prospettica, in cui tutti gli slice passavano interamente per l’ipofisi, 4/9 (44%) erano leggermente iperintense mentre 5/9 (56%) erano nettamente iperintense nelle immagini pesate in T1. A seconda della posizione dello slice (OrC, PAb e RRS), nella maggior parte dei casi l’ipofisi è risultata omogenea se la fetta era OrC, a BS e BS V – Pd se era PAb e disomogenea, ad anello iperitenso, a BS V – NoPd se era RRS. Conclusioni: L’ipofisi di gatto appare iperintensa nelle sequenze RM pesate in T1. La posizione dello slice è fondamentale per visualizzare in maniera chiara l’ipofisi e per evitare la mediazione del volume parziale con strutture retrosellari che potrebbero alterare il segnale RM della ghiandola.

La neuroipofisi del gatto è iperintensa nelle sequenze RM pesate in T1?

ERLA, MATTIA
2023/2024

Abstract

Introduction: The pituitary gland is an intracranial endocrine gland located in the pituitary fossa of the basisphenoid bone and divided into two portions, the adenohypophysis and the neurohypophysis. Most pituitary disorders, at least until they also affect other surrounding structures, can cause silent clinical symptoms. In veterinary neurology, Magnetic Resonance Imaging (MRI) plays a key role in the early diagnosis of these specific afflictions but, compared to other species, the MRI study of the pituitary gland is complicated by the considerable intraspecific anatomical variation and the small size of the gland. Despite this, the few studies on the subject identify the pituitary MRI signal in T1-weighted images as hyperintense. The true nature of this hyperintensity has not yet been fully identified; some studies attribute it to neurosecretory granules of vasopressin, others to lipid droplets of glial cells of the neurohypophysis, still others to the presence of adipose tissue and adipocytes in the basisphenoid bone region. Objective of the study: To analyze the MRI signal of the cat pituitary gland to characterize pituitary intensity in T1-weighted images. To also evaluate how scanning modalities affect the accuracy of MRI images in order to provide useful insights into the best modalities for scanning the feline pituitary gland in Veterinary Medicine. Materials and Methods: Retrospective study of 61 MRIs of European mesocephalic cats and prospective study of 11 MRIs of European mesocephalic cats. Transverse T1-weighted, sagittal T2-weighted, and transverse T2-weighted sequences with no evidence of intracranial pathology were analyzed. Results: Of the 61 retrospective cases, 33/61 (54%) hypophyses were contained within a single slice; of these, 14/33 (42%) were slightly hyperintense while 19/33 (58%) were markedly hyperintense in T1-weighted images. The remaining 28/61 (46%) pituitary glands were bisected by the slice; in the rostral slice, 14/28 (50%) pituitary glands were isointense to the encephalic white matter, 11/28 (39%) were slightly hyperintense and 3/28 (11%) were markedly hyperintense. In the caudal portion, however, 8/28 (29%) pituitary glands were moderately intense while 20/28 (71%) were markedly hyperintense in T1-weighted sequences. In the prospective analysis, in which all slice passed entirely through the pituitary, 4/9 (44%) were mildly hyperintense while 5/9 (56%) were markedly hyperintense in T1-weighted images. Depending on the slice location (OrC, PAb and RRS), in most cases the pituitary was homogeneous if the slice was OrC, with a BS and BS V - Pd if it was PAb and inhomogeneous, hyperintense ring, with a BS V - NoPd if it was RRS. Conclusions: The cat pituitary gland appears hyperintense in T1-weighted MR sequences. The position of the slice is critical to clearly visualize the pituitary gland and to avoid partial volume mediation with retrosellar structures that could alter the MR signal of the gland.
2023
Does feline posterior pituitary gland have a bright spot in T1 weighted MRI?
Introduzione: L’ipofisi è una ghiandola endocrina intracranica situata nella fossa ipofisaria dell’osso basisfenoide e suddivisa in due porzioni, l’adenoipofisi e la neuroipofisi. La maggior parte delle patologie ipofisarie, perlomeno fino a quando non interessano anche altre strutture circostanti, possono causare una sintomatologia clinica silente. In neurologia veterinaria la Risonanza Magnetica (RM) riveste un ruolo fondamentale nella diagnosi precoce di queste specifiche affezioni ma, rispetto alle altre specie, lo studio RM dell’ipofisi è complicato dalla notevole variazione anatomica intraspecifica e dalle ridotte dimensioni della ghiandola. Nonostante ciò, i pochi studi al riguardo identificano come iperintenso il segnale RM ipofisario nelle immagini pesate in T1. La reale natura di questa iperintensità non è ancora stata del tutto identificata; alcuni studi la attribuiscono ai granuli neurosecretori di vasopressina, altri ai droplets lipidici delle cellule gliali della neuroipofisi, altri ancora alla presenza di tessuto adiposo e adipociti nella regione dell’osso basisfenoide. Obiettivo dello studio: Analizzare il segnale RM dell’ipofisi del gatto per caratterizzare l’intensità ipofisaria nelle immagini pesate in T1. Valutare, inoltre, come le modalità di scansione influiscano sull’accuratezza delle immagini RM al fine di fornire indicazioni utili sulle migliori modalità di scansione dell’ipofisi felina in Medicina Veterinaria. Materiali e metodi: Studio retrospettivo di 61 RM di gatti europei mesocefalici e studio prospettico di 11 RM di gatti europei mesocefalici. Sono state analizzate le sequenze pesate in T1 trasverse, T2 sagittali e T2 trasverse senza evidenze di patologie intracraniche. Risultati: Dei 61 casi retrospettivi, 33/61 (54%) ipofisi erano contenute all’interno di un singolo slice; di queste, 14/33 (42%) erano leggermente iperintense mentre 19/33 (58%) erano nettamente iperintense nelle immagini pesate in T1. Le restanti 28/61 (46%) ipofisi erano divise in due dallo slice; nella fetta orale, 14/28 (50%) ipofisi erano isointense alla sostanza bianca encefalica, 11/28 (39%) erano leggermente iperintense e 3/28 (11%) erano nettamente iperintense. Nella porzione aborale, invece, 8/28 (29%) ipofisi erano mediamente intense mentre 20/28 (71%) erano nettamente iperintense nelle sequenze pesate in T1. Nell’analisi prospettica, in cui tutti gli slice passavano interamente per l’ipofisi, 4/9 (44%) erano leggermente iperintense mentre 5/9 (56%) erano nettamente iperintense nelle immagini pesate in T1. A seconda della posizione dello slice (OrC, PAb e RRS), nella maggior parte dei casi l’ipofisi è risultata omogenea se la fetta era OrC, a BS e BS V – Pd se era PAb e disomogenea, ad anello iperitenso, a BS V – NoPd se era RRS. Conclusioni: L’ipofisi di gatto appare iperintensa nelle sequenze RM pesate in T1. La posizione dello slice è fondamentale per visualizzare in maniera chiara l’ipofisi e per evitare la mediazione del volume parziale con strutture retrosellari che potrebbero alterare il segnale RM della ghiandola.
Gatto
Ipofisi
Risonanza Magnetica
File in questo prodotto:
File Dimensione Formato  
Erla_Mattia.pdf

accesso aperto

Dimensione 3.44 MB
Formato Adobe PDF
3.44 MB Adobe PDF Visualizza/Apri

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/74343