A thermal analysis of the plasma Extraction Grid in the SPIDER experiment was carried out using Fiber Bragg Grating (FBG) optical sensors, with the aim of gaining deeper insight into its heating behaviour and dynamics. The study focused on interpreting the signals from experimental tests and comparing them with transient finite element models. Encouraging results were obtained from both thermal simulations and data analysis, suggesting that the plasma beam intensity distribution is correlated with system variables. The findings indicate the potential diagnostic applicability of the thermal signal measured by FBG sensors.
Analisi termica della Griglia di Estrazione di plasma dell'esperimento SPIDER, condotto tramite sensori a fibra ottica FBG, con l’obiettivo di approfondire le modalità e la dinamica del suo riscaldamento. Il lavoro è stato quindi svolto cercando di interpretare i segnali delle prove sperimentali, confrontandoli con modelli ad elementi finiti in condizioni transitorie. Abbiamo ottenuto risultati incoraggianti dai modelli termici e dalla analisi dati, che suggeriscono una distribuzione dell’intensità dei fasci di plasma correlata alle variabili del sistema. I dati ottenuti suggeriscono la potenziale applicabilità diagnostica del segnale termico da FBG.
Analisi termica della griglia di estrazione dell'esperimento SPIDER tramite sensori a fibra ottica: interpretazione del segnale e confronto con modelli ad elementi finiti in condizioni transitorie
LUCCHI, LEONARDO
2024/2025
Abstract
A thermal analysis of the plasma Extraction Grid in the SPIDER experiment was carried out using Fiber Bragg Grating (FBG) optical sensors, with the aim of gaining deeper insight into its heating behaviour and dynamics. The study focused on interpreting the signals from experimental tests and comparing them with transient finite element models. Encouraging results were obtained from both thermal simulations and data analysis, suggesting that the plasma beam intensity distribution is correlated with system variables. The findings indicate the potential diagnostic applicability of the thermal signal measured by FBG sensors.| File | Dimensione | Formato | |
|---|---|---|---|
|
Lucchi_Leonardo.pdf
accesso aperto
Dimensione
5.39 MB
Formato
Adobe PDF
|
5.39 MB | Adobe PDF | Visualizza/Apri |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/92867