The MUonE experiment was proposed with the aim of studying muon-electron collisions in order to determine some radiative corrections affecting both the scattering process and the anomalous magnetic moment of the muon. The final state of the interaction will be analyzed using a tracking system for trajectory reconstruction and an electromagnetic calorimeter for electron–muon discrimination. For the latter, a prototype consisting of 25 counters was built, each composed of a lead tungstate crystal read out by an avalanche photodiode (APD). Test measurements with the prototype were carried out both by illuminating the counters with a laser and by exposing them to electron or muon beams. The analysis of the collected data makes it possible to estimate the calorimeter performance in terms of efficiency, stability, and resolution. Furthermore, an analysis performed immediately after data acquisition can promptly identify possible issues and allow the necessary corrections to be applied. The analysis tools are therefore developed within the same environment used by the data acquisition system, in order to realize a single integrated framework for data acquisition and analysis.
L'esperimento MUonE è stato proposto con l'obiettivo di studiare le collisioni muone su elettrone, al fine di determinare alcune correzioni radiative che influenzano sia il processo di scattering che il momento magnetico anomalo del muone. Lo stato finale dell'urto verrà analizzato mediante un sistema di tracciatori, per la ricostruzione delle traiettorie, ed un calorimetro elettromagnetico per la discriminazione dell'elettrone dal muone. Per quest'ultimo è stato realizzato un prototipo costituito da 25 contatori composti da un cristallo di tungstato di piombo letto da un fotodiodo a valanga (APD). Misure di test con il prototipo sono state eseguite sia illuminando i contatori con un laser che su fascio di elettroni o muoni. L'analisi dei dati raccolti consente di stimare le prestazioni del calorimetro in efficienza, stabilità e risoluzione. Una analisi dei dati immediatamente successiva alla raccolta dei dati stessi può inoltre consentire di identificare prontamente eventuali problemi ed apportare le correzioni necessarie. Gli strumenti di analisi vengono quindi sviluppati nello stesso ambiente utilizzato dal sistema di acquisizione per realizzare un unico sistema integrato di acquisizione e analisi.
Analisi dei dati raccolti con il calorimetro per l’esperimento MUonE
LEZUO, SOFIA
2025/2026
Abstract
The MUonE experiment was proposed with the aim of studying muon-electron collisions in order to determine some radiative corrections affecting both the scattering process and the anomalous magnetic moment of the muon. The final state of the interaction will be analyzed using a tracking system for trajectory reconstruction and an electromagnetic calorimeter for electron–muon discrimination. For the latter, a prototype consisting of 25 counters was built, each composed of a lead tungstate crystal read out by an avalanche photodiode (APD). Test measurements with the prototype were carried out both by illuminating the counters with a laser and by exposing them to electron or muon beams. The analysis of the collected data makes it possible to estimate the calorimeter performance in terms of efficiency, stability, and resolution. Furthermore, an analysis performed immediately after data acquisition can promptly identify possible issues and allow the necessary corrections to be applied. The analysis tools are therefore developed within the same environment used by the data acquisition system, in order to realize a single integrated framework for data acquisition and analysis.| File | Dimensione | Formato | |
|---|---|---|---|
|
Lezuo_Sofia.pdf
accesso aperto
Dimensione
3.93 MB
Formato
Adobe PDF
|
3.93 MB | Adobe PDF | Visualizza/Apri |
The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License
https://hdl.handle.net/20.500.12608/114443