The study focuses on the evaluation of lower limb lymphedema, a chronic condition characterized by fluid accumulation in the tissues due to a malfunction of the lymphatic system. The aim of the thesis is to compare the effectiveness of the Six Minute Walking Test (6MWT) and the modified Timed Up and Go Test (modified TUG) as a means of assessing lower limb functionality in patients with lymphedema admitted to the Asiago hospital. Traditionally, the 6MWT has been used, but we wanted to verify whether the modified TUG, being quicker to perform, could be more functional in detecting improvements in lymphedema. The study involved patients undergoing an intensive rehabilitation cycle with multicomponent bandages, manual therapy and physical activity. The tests were administered at the beginning and end of treatment, and the data collected included weight, volume and test execution times. The results show that the modified TUG is more effective in detecting improvements in functional mobility, with significant reductions in execution times. In contrast, the 6MWT showed progress in walking distance, reflecting an increase in physical endurance. In conclusion, both tests are useful for monitoring the progress of patients with lymphedema, but they measure different aspects of function. The combination of both tests, integrated with volumetric and centimeter measurements of limbs and weight, provides a comprehensive assessment of the clinical improvements of patients during hospitalization.

Lo studio si concentra sulla valutazione del linfedema agli arti inferiori, una condizione cronica caratterizzata da accumulo di liquidi nei tessuti a causa di un malfunzionamento del sistema linfatico. L'obiettivo della tesi è quello di confrontare l'efficacia del Six Minute Walking Test (6MWT) e del Timed Up and Go Test modificato (TUG modificato) come mezzo per valutare la funzionalità degli arti inferiori nei pazienti affetti da linfedema ricoverati presso l'ospedale di Asiago. Tradizionalmente è stato utilizzato il 6MWT, ma si è voluto verificare se il TUG modificato, essendo più rapido da eseguire, potesse risultare più funzionale nel rilevare i miglioramenti del linfedema. Lo studio ha coinvolto pazienti sottoposti a un ciclo riabilitativo intensivo con bendaggi multicomponente, terapia manuale e attività fisica. I test sono stati somministrati all'inizio e alla fine del trattamento, e i dati raccolti includevano misurazioni di peso, volume e tempi di esecuzione dei test. I risultati mostrano che il TUG modificato è più efficace nel rilevare miglioramenti nella mobilità funzionale, con riduzioni significative nei tempi di esecuzione. Invece, il 6MWT ha evidenziato progressi nella distanza percorsa, riflettendo un aumento della resistenza fisica. In conclusione, entrambi i test sono utili per monitorare i progressi dei pazienti con linfedema, ma misurano aspetti differenti della funzionalità. La combinazione di entrambi i test, integrata con le misurazioni volumetriche e centimetriche degli arti e del peso, offre una valutazione completa dei miglioramenti clinici dei pazienti durante il ricovero.

CORRELAZIONE TRA TIME UP AND GO TEST MODIFICATO (20 METRI) E MIGLIORAMENTO DELL’EDEMA DEGLI ARTI INFERIORI IN PAZIENTI AFFETTI DA LINFEDEMA RICOVERATI IN MFR OSPEDALE DI ASIAGO AULSS 7

CONTRO, ANDREA
2023/2024

Abstract

The study focuses on the evaluation of lower limb lymphedema, a chronic condition characterized by fluid accumulation in the tissues due to a malfunction of the lymphatic system. The aim of the thesis is to compare the effectiveness of the Six Minute Walking Test (6MWT) and the modified Timed Up and Go Test (modified TUG) as a means of assessing lower limb functionality in patients with lymphedema admitted to the Asiago hospital. Traditionally, the 6MWT has been used, but we wanted to verify whether the modified TUG, being quicker to perform, could be more functional in detecting improvements in lymphedema. The study involved patients undergoing an intensive rehabilitation cycle with multicomponent bandages, manual therapy and physical activity. The tests were administered at the beginning and end of treatment, and the data collected included weight, volume and test execution times. The results show that the modified TUG is more effective in detecting improvements in functional mobility, with significant reductions in execution times. In contrast, the 6MWT showed progress in walking distance, reflecting an increase in physical endurance. In conclusion, both tests are useful for monitoring the progress of patients with lymphedema, but they measure different aspects of function. The combination of both tests, integrated with volumetric and centimeter measurements of limbs and weight, provides a comprehensive assessment of the clinical improvements of patients during hospitalization.
2023
CORRELATION BETWEEN MODIFIED TIME UP AND GO TEST (20 METERS) AND IMPROVEMENT OF LOWER LIMB EDEMA IN PATIENTS WITH LYMPHEDEMA HOSPITALIZED IN MFR ASIAGO HOSPITAL AULSS 7
Lo studio si concentra sulla valutazione del linfedema agli arti inferiori, una condizione cronica caratterizzata da accumulo di liquidi nei tessuti a causa di un malfunzionamento del sistema linfatico. L'obiettivo della tesi è quello di confrontare l'efficacia del Six Minute Walking Test (6MWT) e del Timed Up and Go Test modificato (TUG modificato) come mezzo per valutare la funzionalità degli arti inferiori nei pazienti affetti da linfedema ricoverati presso l'ospedale di Asiago. Tradizionalmente è stato utilizzato il 6MWT, ma si è voluto verificare se il TUG modificato, essendo più rapido da eseguire, potesse risultare più funzionale nel rilevare i miglioramenti del linfedema. Lo studio ha coinvolto pazienti sottoposti a un ciclo riabilitativo intensivo con bendaggi multicomponente, terapia manuale e attività fisica. I test sono stati somministrati all'inizio e alla fine del trattamento, e i dati raccolti includevano misurazioni di peso, volume e tempi di esecuzione dei test. I risultati mostrano che il TUG modificato è più efficace nel rilevare miglioramenti nella mobilità funzionale, con riduzioni significative nei tempi di esecuzione. Invece, il 6MWT ha evidenziato progressi nella distanza percorsa, riflettendo un aumento della resistenza fisica. In conclusione, entrambi i test sono utili per monitorare i progressi dei pazienti con linfedema, ma misurano aspetti differenti della funzionalità. La combinazione di entrambi i test, integrata con le misurazioni volumetriche e centimetriche degli arti e del peso, offre una valutazione completa dei miglioramenti clinici dei pazienti durante il ricovero.
Linfedema
TUG
Arti inferiori
File in questo prodotto:
File Dimensione Formato  
CORRELAZIONE TRA TIMED UP AND GO TEST MODIFICATO (20 METRI) E MIGLIORAMENTO DELL’EDEMA DEGLI ARTI INFERIORI IN PAZIENTI AFFETTI DA LINFEDEMA RICOVERATI IN MFR OSPEDALE DI ASIAGO AULSS 7.pdf

accesso aperto

Dimensione 660.62 kB
Formato Adobe PDF
660.62 kB Adobe PDF Visualizza/Apri

The text of this website © Università degli studi di Padova. Full Text are published under a non-exclusive license. Metadata are under a CC0 License

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12608/80542